Faults - GE GFWS2500 Technical Service Manual

Louisville built front load washer
Table of Contents

Advertisement

Faults A-11
Fault
Name
Code
Hex
A
Slow Fill (Flow
Meter)
B
Drain Pump
C
Overfl ow Condition Water level went above
D
Inverter Communi-
cation Timeout
E
Door Open
F
Door Unlocked
10
Max Water Volume More than 13 gallons
11
Door Lock Error
Description
Slow fi ll during fl ow
meter fi ll.
Water remaining it tub. • Check drain pump clean out.
the overfl ow level on 2
separate occasions.
The UI has not received
the inverter status
message in 10 seconds.
While the unit was
running the door was
detected as open.
While the unit was
running the door was
detected as unlocked.
of water entered tub.
Max Water Volume is
reset each time the unit
drains
Door fails to lock after
more than 3 attempts.
Repair Action
• Check house water supply and proper water
pressure.
• Check for kinked hoses.
• Check hose and water valve screens.
• Check fl ow meter wiring.
• Replace fl ow meter.
• Replace IMC board.
• Check installation instructions for proper
standpipe height.
• Check pressure sensor frequency.
• Check for water valve sticking open.
• Check pressure sensor frequency.
• Reset control boards by unplugging the
washer for 30 seconds.
• Check the wiring between the IMC and UI
boards.
• If still no operation, replace IMC (Inverter
Machine Control).
• Ensure proper loading (Unbalanced loads can
cause this).
• Check for door closing properly or warped
door.
• Check door lock and wiring.
• Ensure proper loading (Unbalanced loads can
cause this).
• Check for door closing properly or warped
door.
• Check door lock and wiring.
• Check fl ow meter and fl ow meter wiring.
• Check pressure sensor, pressure sensor
wiring and pressure sensor hose.
• Replace pressure sensor.
• Replace fl ow meter.
• Replace IMC board.
• Check for door closing properly or warped
door.
• Check for broken or deformed door latch.
• Check door lock and wiring.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents