Rj45 Board; Rj45 Board Strip Circuit; Rj45 Board Removal - GE GFWS2500 Technical Service Manual

Louisville built front load washer
Table of Contents

Advertisement

7. Disconnect IMC wire harnesses and remove IMC
board.

RJ45 Board

Operating Voltage: 12 VDC & 7.5 VDC
Location: See RJ45 Board Location on page 35.
The RJ45 is used to interface the washer control
board to other types of computer systems. The
RJ45 board requires +12 VDC, +7.5 VDC, COMM and
DC GND to operate. These voltages are generated
on the IMC board and supplied to the RJ45 board
through the UI board.
Pressure Sensor
Pressure Sensor Hose

RJ45 Board Strip Circuit

L1
IMC J101-3
N
IMC J101-2
RJ45 J203-1
UI J201-8
+12 VDC
RJ45 J203-2
COMM
UI J201-7
RJ45 J203-3
UI J201-6
DC GND

RJ45 Board Removal

1. Disconnect power to the unit.
2. Remove the control panel. (See Control Panel
Removal)
3. Remove the top panel. (See Top Panel Removal)
4. Disconnect the RJ45 wire harness.
5. Remove the RJ45 board mounting screw.
48
IMC Board
IMC J103-4
IMC J103-3
IMC J103-2
IMC J103-1
UI Board
+12 VDC
UI J201-5
+7.5 VDC
UI J201-2
COMM
UI J201-3
DC GND
UI J201-1