sump hose.
10. Remove the two 1/4" pump housing mounting
screws.
1/4" Hex
11. Slide the pump housing backward to disengage
the front locator pins.
12. Remove the three T-20 pump screws and re-
move the pump.
1/4" Hex
Operating Voltage: 120 VAC
Resistance: 14.8 Ω
Recirculation Pump
Locator Pin
Recirculation pump operation is controlled by a
relay on the IMC board. Recirculation pump opera-
tion is monitored by the IMC through the pressure
sensor. Before the recirculation pump starts, the IMC
board records the current pressure sensor reading.
When the recirculation pump is started, the IMC
board looks for the pressure sensor reading to drop
slightly. If this drop does not occur, the IMC sets a
recirculation pump error code.
To Neutral
67
Recirculation Pump
Drain Pump Location (Front View)
Drain Pump
Recirculation Pump Strip Circuit
IMC J701-3
IMC J101-2
Recirculation Pump
R