Installation; Appropriate Installation Location; Ventilation Hose And Connection (For Products Equipped With An Outlet Vent) - Beko DV 1572 X User Manual

Table of Contents

Advertisement

3

Installation

Refer to the nearest Authorised Service Agent for
installation of your product.
C
Preparation of location and electrical
installation for the product is under
customer's responsibility.
B
Installation and electrical connections must
be carried out by a qualified personnel.
Prior to installation, visually check if the
A
product has any defects on it. If so, do not
have it installed. Damaged products will
cause risks for your safety.

3.1 Appropriate installation location

• Install the product in an environment which has no
risk of freezing and is in a stable and level position.
• Operate your product in a well ventilated, dust-free
environment.
• Do not block the air ducts in front of and under the
product with materials such as long pile rugs and
wooden bands.
• Do not place your product on a long pile rug or on
similar surfaces.
• Do not install the product behind a door with a lock,
sliding door or a hinged door which can strike the
product.
• Once the product is installed, it should stay at the
same place where its connections have been made.
When installing the product, make sure that the
rear wall of it does not touch anywhere (tap, socket,
etc.) and also pay attention to install the product at
a place where it will stay permanently.
B
Do not place the product on top of the power
cable.
• Keep at least 1.5 cm distance to walls of other
furniture.
Under counter installation
• A special part (Part no: 295 970 0100) replacing
the top trim must be provided and installed by
the Authorised Service Agent in order to use the
machine under a counter or in a cupboard. It should
never be operated without the top trim.
• Leave at least 3 cm of space between the side
and rear walls of the product and the walls of the
counter/cupboard when installing your product
under a counter or in a cupboard.
14 / 28 EN
3.2 Ventilation hose and connection
(for products equipped with an outlet
vent)
Ventilation hose allows exhaust air from inside the
machine
Vented dryer has 1 air outlet.
Stainless sheet metal or aluminum pipes can be
used instead of a hose. The pipe diameter should be
minimum 10 cm.
Maximum hose and pipe lengths are given in the table
below.
Maximum length
1 elbow 45°
1 elbow 90°
1 elbow 90° short
1 wall passage
C
Each elbow and other passages should be
subtracted from the maximum length stated
above.
To connect a ventilation hose;
1. Connect the air outlet hose to the hose spacer piece
by turning it counterclockwise.
2. Make the hose passages as shown below.
C
Exhaust of humid air from the dryer into the
room is inconvenient. It may damage the walls
and furniture in the room.
C
The ventilation hose can be routed outdoors
via a window or it can be connected to the air
outlet in the bathroom.
C
Air outlet hose must be routed directly to the
outdoors. There must be a limited number of
elbows as not to hinder ventilation.
C
To prevent water accumulation in the hose,
make sure that it is not folded on the floor.
Hose
Pipe
4 m
5 m
-1.0 m
-0.3 m
-1.8 m
-0.6 m
-2.7 m
-2.0 m
-2.0 m
Dryer / User Manual

Hide quick links:

Advertisement

Table of Contents
loading