Specifications - Cornelius MILLENNIUM MJ41-6PB Installation & Service Manual

Table of Contents

Advertisement

Model Number ........................................................MJ40-6 – 115 VAC/1 Phase 60Hz, 8.0 Amps
Electrical Ratings ....................................................MJ42-6 – 230 VAC/1 Phase/50 Hz, 4.0 Amps
.................................................................................MJ41-6 – 200 VAC/1 Phase/60 Hz, 4.0 Amps
Electrical Connection ..............................................3 Prong Plug w/Ground Supplied 120v/60
.................................................................................2 Amp Prong w/Ground Supplied with Export Models
Power Supply ..........................................................15 Amps at 120 volts or 10 Amps at 220 volts
Water Requirements ................................................3/8 in. (9.5 mm.) SAE male flare inlet
.................................................................................20-100psi (1.4-7bar) max. static pressure
.................................................................................3.0 oz. (88.7 ml.) water flow per second
Refrigeration............................................................10.5 oz. R-134a Refrigerant
.................................................................................1/3 hp. Compressor
.................................................................................Test Pressures:
.................................................................................
.................................................................................
.................................................................................Air Cooled Condenser
Recommended Clearance ........................................4 in. (10.16 cm.) on top
Weight .....................................................................Shipping, 160 lbs. (72.6 kg.)
.................................................................................Operation, 266 lbs. (120.7 kg.)
Approvals ................................................................U.L., C.U.L., N.S.F.
* Low speed rating is 2/3 of the high speed

Specifications

3
High
460 psi (31.2 bar)
Low
200 psi (13.5 bar)