ELECTRICAL DATA
OPER.
VOLTAGE
UNIT SIZE
V --- PH--- HZ
MAX / MIN
9K
127 / 104
115--- 1---60
12K
12K
017K (HP) /
253 / 187
208---230---1---60
018K (AC)
22K
CONNECTION DIAGRAMS
L
N
Indoor
Indoor Unit
Signal
Power Supply
High
115-1-60
Voltage
9K and 12K 115V INDOOR UNIT
L1
S
L2
Indoor Unit
Indoor
Power Supply
Signal
High
Voltage
208-230-1-60
12K to 22K 208-230V INDOOR UNIT
Notes:
1. Do not use thermostat wire for any connection between indoor and outdoor units.
2. All connections between indoor and outdoor units must be as shown. The connections are sensitive to polarity and will result in a fault code.
COMPRESSOR
RLA
LRA
V --- PH--- HZ
5.30
10
115---1---60
5.30
10
3.95
14
208---230---1---60
9.70
17
CONNECTING CABLE
OUTDOOR TO INDOOR
GND
S
Ground
CONNECTING CABLE
OUTDOOR TO INDOOR
GND
Ground
Fig. 12 --- Connection Diagrams
OUTDOOR FAN
FLA
HP
W
V --- PH--- HZ
0.7
0.31
23
115---1---60
0.3
0.33
24
0.6
0.68
50
208---230---1---60
0.6
0.72
53
1(L)
Power to
Indoor Unit
115-1-60
9K and 12K 115V OUTDOOR UNIT
L1
Power to
Indoor Unit
208-230-1-60
12K to 22K 208-230V OUTDOOR UNIT
9
INDOOR FAN
MCA
FLA
HP
W
0.3
0.020
15
19
0.2
0.027
20
10
0.3
0.038
28
14
0.4
0.061
45
16
115-1-60
FIELD POWER SUPPLY
GND
2(N)
S
L
N
Indoor
Main
Signal
Power Supply
High
115-1-60
Voltage
208-230-1-60
FIELD POWER SUPPLY
GND
L2
S
L1
L2
Main
Indoor
Signal
Power Supply
High
Voltage
208-230-1-60
MAX FUSE
CB AMP
30
15
20
25