Installation Tips; Indoor Unit Installation - Carrier 40MFC Installation Instructions Manual

Hide thumbs Also See for 40MFC:
Table of Contents

Advertisement

INSTALLATION TIPS

Ideal installation locations include:
Indoor Unit
S A location where there are no obstacles near inlet and outlet area.
S A location which can bear the weight of indoor unit.
S Do not install indoor units near a direct source of heat such as
direct sunlight or a heating appliance.
S A location which provides appropriate clearances as outlined in
Fig. 1.
Outdoor Unit
S A location which is convenient to installation and not exposed to
strong wind.
S A location which can bear the weight of outdoor unit and where
the outdoor unit can be mounted in a level position.
S A location which provides appropriate clearances as outlined in
Fig. 2.
S Do not install the indoor or outdoor units in a location with
special environmental conditions. For those applications, contact
your Ductless Split representative.

INDOOR UNIT INSTALLATION

INSTALL MOUNTING PLATE
The mounting plate will look like one of the following depending
on model size:
6 (150) or more to ceiling
6.7 (170)
5 (130)
or more to wall
Left rear side
refrigerant pipe
hole
2.6 (65)
26.8 (680)
Fig. 3 --- Mounting Plate- - Model size 009
6 (150) or more to ceiling
6.7 (170)
5 (130)
or more to wall
Left rear side
refrigerant pipe
hole
2.6 (65)
30.3 (770)
Fig. 4 --- Mounting Plate- - Model size 012
6 (150) or more to ceiling
3.2 (80)
5 (130)
or more to wall
Left rear side
refrigerant pipe
35.6 (905)
hole
2.6 (65)
Fig. 5 --- Mounting Plate- - Model sizes 017 (AC) / 018 (HP)
6 (150) or more to ceiling
Indoor unit outline
11.5 (292)
Installation plate
5 (130)
or more to wall
Left rear side
refrigerant pipe
hole
2.6 (65)
40.6 (1030)
Fig. 6 --- Mounting Plate- - Model size 022
Indoor unit outline
3.6 (92)
5 (130)
or more to wall
Right rear side
refrigerant pipe
hole
2.6 (65)
in. (mm)
A14345
Indoor unit outline
3.7 (95)
5 (130)
or more to wall
Left rear side
refrigerant pipe
hole
2.6 (65)
in. (mm)
A14346
Indoor unit outline
3.9 (100)
5 (130)
or more to wall
Left rear side
refrigerant pipe
hole
2.6 (65)
in. (mm)
A14347
6.4 (163)
5 (130)
or more to wall
Left rear side
refrigerant pipe
hole
2.6 (65)
in. (mm)
A14348
1. Carefully remove the mounting plate, which is attached to
the back of the indoor unit.
2. The mounting plate should be located horizontally and level
on the wall. All minimum spacings shown in Fig. 1 and 3
through 6 should be maintained.
3. If the wall is block, brick, concrete or similar material, drill
.2" (5 mm) diameter holes and insert anchors for the ap-
propriate mounting screws.
4. Attach the mounting plate to the wall.
DRILL HOLE IN WALL FOR INTERCONNECTING
PIPING, DRAIN AND WIRING
Refrigerant Line Routing
The refrigerant lines may be routed in any of the four directions
shown in Fig. 8.
For maximum serviceability, it is recommended to have refrigerant
line flare connections and the drain connections on the outside of
the wall that the fan coil can be mounted on.
If piping is going through the back:
1. Determine pipe hole position using the mounting plate as a
template. Drill pipe hole diameter per values given in Fig.
3 through 6. The outside pipe hole is 1/2- -in. (13 mm) min.
lower than inside pipe hole, so it slants slightly downward
(see Fig. 7).
INDOOR
Fig. 7 --- Drill Holes
If piping is going through the right or left side:
1. Use a small saw blade to carefully remove the correspond-
ing plastic covering on side panel and drill the appropriate
size hole where the pipe is going through the wall.
Pipe holder
Pipe cover
2
1
Right piping
Fig. 8 --- Piping Locations
7
1/2 in. (13 mm)
Min.
OUTDOOR
Pipe cover
4
Left piping
3
Left back piping
Right back piping
A07371
A14349