Specifications-Indoor Dome - American Dynamics SpeedDome Ultra 8 Installation And Service Manual

Hide thumbs Also See for SpeedDome Ultra 8:
Table of Contents

Advertisement

Specifications-Indoor Dome

Operational
Pan/Tilt:
Manual pan speed................. 0.25°-100° per second
Manual tilt speed.................... 0.25°-100° per second
Preset pan speed:............360° per second maximum
Preset tilt speed............... 220° per second maximum
Pan travel............................. 360° continuous rotation
Tilt travel............................................................. 110°
Pan/Tilt accuracy................................................ ±0.5°
Auto synchronization:
Line locked.................... Remote V-phase adjustment
Internal.................................... Built-in sync generator
Up-the-coax........................................... System sync
Address range.......................... 1-99 (RS-422/RS-485),
1-64 (Manchester), 1-255 (SensorNet)
AD-UTC (based on number of inputs)
Preset access tim e................<1 second to position.
Programmable patterns......... Up to 16 depending on
Program storage.................... 2 Mbytes of Flash
Data storage.......................... 256 Kbytes of SRAM
Menu languages.................... English, French, German,
Electrical
Input voltage.................................... 18-30Vac, 50/60Hz
Power consumption....................................... 11W max.
Current.................................................. 0.77A @ 16Vac
Power on in-rush current........................................ 1.5A
Allowable drop out.............................................. 100ms
SPEEDDOME ULTRA 8 CAMERA DOME
INSTALLATION AND SERVICE GUIDE
(scaled to zoom position)
(scaled to zoom position)
Full zoom in <4 seconds.
Focus on dome saved
presets in <1 second.
Focus on controller saved
presets in <7 seconds
host
memory
Spanish, Italian, and
Portuguese
NEC Class 2, LPS
27 OF 30
Surge Protection:
Design tolerance................. 16-36Vac, 50/60Hz
Video output......................... Low capacitance Zener
Power line............................ TVS rated at 60V, 1.5
RS-422................................. TVS rated at 9.8V/1A,
Manchester/
SensorNet 485..................... Gas discharge tube rated
Alarm input........................... TVS rated at 9.8V/1A,
Alarm s Inputs/Control Outputs:
Inputs...................................... 4 opto-isolated; requires
Outputs..................................... 3 open collector drivers
Environmental
Operating temperature.......-10° to 50°C (14° to 122°F)
Relative humidity................... 0 to 95% non-condensing
Storage temperature............................... -20°C to 65°C
Mechanical
Height (TBD).............................................. 205mm (8in)
Eyeball diameter..................................... 120mm (4.7in)
Weight:
Housing and eyeball.......................... 1.09kg (2.4 lbs)
Base (with I/O board)...................... 0.16kg (0.35 lbs)
Lens and Bubble Densities
Eyeball Lens................................................................ f0
Bubbles:
ADSDUCLR (Clear)................................................. f0
ADSDUSMK (Smoke)........................................... f0.5
suppressor 6.5V, 1500W
joules, 250A 8/20js
impulse
20V/25A, 500W, 8/20js
impulse
at: 8/20|js impulse
discharge current of 10kA,
ten 8/20js impulse
discharge current of 5kA
Isolation transformer
coupled 2000Vrms.
PTC fuse protects
transformer. TVS rated at
9.8V/1A, 20V/25A, 500W,
8/20js impulse
20V/25A, 500W, 8/20js
impulse
3.5mA sink to ground
@ 30Vdc, 40mA
(-4°F to 149°F)
8200-0600-03, REV. F1

Advertisement

Table of Contents
loading