NSF-approved Cleaning and Sanitizing Procedure –––––––––––––––––––––––
Cleaning and sanitizing should be performed at least every 6 months (more often
if local water conditions dictate) .
WARNING!
§ Place the dispenser in Maintenance Mode prior to servicing or
cleaning the ice machine. See
page
12.
§ For protection, rubber gloves and safety goggles (and/or face shield)
should be worn when handling SafeCLEAN Plus™.
§ Do not use bleach, it will damage the dispenser.
Required Supplies
§ 7 Series: 21 oz . (0 .621 L) or 3 packets SafeCLEAN Plus
15 Series: 42 oz . (1 .24 L) or 6 packets SafeCLEAN Plus
§ Funnel and Bucket
Ice machine and Dispenser
1 . Dispense all the ice out of the unit .
2 . Press and hold maintenance/clean switch until
interface to enter Maintenance Mode .
3 . Remove (unscrew) chrome ice dispense chute (Fig . 14 .1) .
4 . Remove drip tray (Fig . 14 .2) .
5 . Remove (2) screws located behind the drip tray (Fig . 14 .3) .
6 . Move front panel and place on top or beside unit (Fig . 14 .4) .
7 .
Remove plug cap from the end of drain tube (Fig . 14 .5) and lower tube
to drain water into bucket . After the system has been drained of water
replace plug cap in drain tube .
8 . Secure tube in holder .
9 . Remove cap from bin lid cover (Fig . 14 .6) .
10 . Screw bin lid cover cap onto ice discharge chute (Fig . 14 .7) .
11 . 7 Series: Mix 21 oz . (0 .621 L) or 3 packets SafeCLEAN Plus with three gallons (11 .4 L) of water .
15 Series: Mix 42 oz . (1 .24 L) or 6 packets SafeCLEAN Plus with six gallons (22 .7 L) of water
12 . Pour cleaning solution into bin lid access spout until solution reaches the spout neck .
13 . Allow the solution to remain in unit for 15 minutes .
14 . While machine is cleaning, remove top and right side panel to access and clean air-cooled condenser .
15 . Submerge ice dispense chute in the remainder of solution for 2 minutes . Rinse with clean, potable water .
16 . Drain system by lowering drain tube into bucket .
17 . Secure drain tube into holder .
18 . Fill and drain three times with potable water . Secure drain tube .
19 . Place a bucket under the dispense chute and remove cap . Note: Some solution will remain and drain out
when cap is removed . Reposition cap on bin lid spout .
20 . Reinstall front panel, ice dispense chute, and drip tray .
21 . Press and hold maintenance/clean switch to exit Maintenance Mode .
14
Dispenser and Icemaker 7CI100A/7FS100A, 15CI100A/15FS100A