12
Tension release
.07.08
Requirement
When solenoid 1 is activated, the tensions disks 3 should be at a distance of at least
0.5 mm from each other.
2
Fig. 12 - 46
● Activate magnet 1.
● Adjust magnet 1 (screws 2) in accordance with the requirement.
1
The point of time for releasing the tension can be set with the service functions,
see Chapter 12.08 Parameter settings.
Adjustment
3
12 - 50