(12) RFID wireless power level

When the B-9704-RFID-U1-US/EU is installed.
RESTART
FEED
0 to 255
Set the wireless power level from the RFID module. When the value is "0", the power is the
weakest and when "255", the power is the strongest. The factory setting is 251.
In the case of the B-9704-RFID-U1-EU-R, the factory default is 50.
When the B-SX704-RFID-U2 is installed.
RESTART
FEED
18 to 26
When the value is "18", the power is the weakest and when "26", the power is the strongest.
The factory default is 20.
The optimal value is different depending on the tags used. Usually it is not necessary to change
this value but changing the value sometimes can increase the number of successful read/write
times.

(13) RFID AGC threshold setting

Available only when the B-SX704-RFID-U2 is installed.
RESTART
FEED
0 to 15
Obtain the gain of the RFID tag, and when that gain is lower than the AGC threshold, tags
are considered as error tags even if a data write succeeds.
When the AGC threshold is se to "0", all tags are writable. When set to 8, for example, only
tags with the AGC threshold level set to 8 or greater are writable.
The optimal value is different depending on the tags. The factory default is 0.
• 255
• 252
• Initial value (251)
• 250
• 0
• 26
• 18
• Initial value (26)
• 25
• 18
• 15
• 1
• Initial value (0)
• 15
• 1