•
If circuit is open, problem is with Ventilation
Motor or wiring (See
•
If resistance is approximately 100 , replace
the Motor Capacitor.
Disassembly
To remove the Ventilation Motor:
1. Remove the oven. (See
Note: In the following step, the exhaust adapter with
damper is not used on recirculating installations.
2. Remove the 2 Phillips-head screws and the
exhaust adapter with damper from the oven.
3. Remove the 3 Phillips-head screws from the
blower plate.
4. Slide the blower plate from under its retaining
À ange.
Flange
5. Remove the 2 Phillips-head screws that attach
the ventilation motor to the back of the oven.
View From Rear
6. Lift up the ventilation motor and place it on top
of the oven as shown below.
) to motor.
Wiring Diagram
.)
Oven Removal
– 52 –
Note: The ventilation motor electrical disconnect is
located inside the Outer Cover.
7. Locate the lock tab on top of the disconnect
and position a À at blade screwdriver as shown
below.
8. Using the blower opening in the Outer Cover as
a pivot point, carefully press down on the lock
tab while disconnecting the electrical connector.
Disconnect
Ventilation Motor Capacitor
•
Location (See
Top View
•
120 VAC
•
If Ventilation Motor is humming and not moving,
(but can still be hand started), check capacitor,
capacitor wiring to motor, and motor windings.
Lock Tab
Pivot Point
.)
(Continued Next Page)