Bottom Tco (Thermal Cut Out) - GE Advantium PSA2200R Technical Service Manual

240 v (atc)
Hide thumbs Also See for Advantium PSA2200R:
Table of Contents

Advertisement

Oven TCO removal:
1. Remove the 3 Phillips-head screws from the Air
Tunnel Outlet. (See
Air Tunnel Outlet
2. Turn the Air Tunnel Outlet over.
3. Disconnect wiring to the Oven TCO.
4. Remove the Phillips-head screw that attaches
the TCO to the metal plate.
5.
Slide the TCO out from the tab.
Air Tunnel Outlet
Oven TCO
Magnetron TCO (Thermal Cut Out)
Location (See
Right Side View
Automatically shuts off oven in case the
magnetron tube overheats.
If the magnetron TCO opens, it will disable all
oven functions including the display.
Normally closed.
Opens 320°F, non-resettable.
To remove the Magnetron TCO:
1. Pivot the Control Panel Assemblyout from the
oven. (See
Control Panel Removal
2. Disconnect wiring from the Magnetron TCO.
3. Remove the Phillips-head screw that attaches
the Magnetron TCO to the air guide, then pull the
TCO towards the bottom.
.)
Disconnect 2 Wires
.)
.)
– 37 –
Magnetron TCO

Bottom TCO (Thermal Cut Out)

Location - On the base behind the control panel.
(See photo below.)
Used to disable oven in the event of a cooktop
¿ re. Purpose is to keep the ventilation fan from
sucking À ames into the oven.
If the Bottom TCO opens, it will disable all oven
functions including the display.
Normally closed.
Opens 320°F, non-resettable.
To remove the Bottom TCO:
1. Pivot the Control Panel Assemblyout from the
oven. (See
Control Panel Removal
2. Disconnect wiring from the Bottom TCO.
3. Remove the Phillips-head screw that attaches
the Bottom TCO to the oven, then pull the TCO
towards the right.
Disconnect
Bottom TCO
Disconnect
Disconnect
.)
Disconnect
(Continued next page)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Advantium psa2201rAdvantium zsa2201r

Table of Contents