Troubleshooting
If all relays are not closing, see
If one or more (but not all) relays are not closing, see
,
Single Relay Not Closing
If all Cooking relays are not closing, see
.
Not Closing
If the Buzzer is not working, see
Note: To gain better access to components, remove
the wires that plug onto the large relays on the
Relay Board. (See
Relay Board.
the Smart Board CN103 wire harn ess (See
.) is routed through.
Board
All Relays Not Closing:
Check voltage between Relay Board CN5 pins 1
and 3.
If 120 VAC is not present, the wire between Relay
Board CN5 pin 3 and neutral output of Noise Filter 1
is open.
If 120 VAC is present, continue to next check.
Check voltage between Relay Board CN01 pins 2
and 4.
If 12 VDC is present, replace the Smart Board.
If 12 VDC is not present, Smart Board is not
supplying relay operating voltage. (See
troubleshooting section.)
Board
Single Relay Not Closing
Locate the inoperative relay in the Relay Chart in
next column.
Check voltage between the selected relay pin and
Relay Board CN01 pin 4.
If 5 VDC is present, replace Relay Board.
If 5 VDC is not present, replace Smart Board.
Note: For situations where the above mentioned 5
VDC is not present, some relays operate loads that
can be controlled by the consumer from the Glass
Touch Assembly. If the in-operative relay is such,
make sure the option is selected at the key panel. If
it is, and the relay is still inoperative, check harness
between Glass Touch Assembly and Smart Board.
If harness is OK, replace Glass Touch Assembly and
Smart Board.
.
All relays not closing
Relay Enable
.

Buzzer

) Cut the wire tie that
Smart
Smart
– 29 –
Relay Chart
Relay
Cavity Light Relay
Cooktop Lamp Bright Relay
Cooktop Lamp Night Relay
Turntable Motor Relay
Damper Motor Relay
Convection Motor Relay
Magnetron Fan Motor and Stirrer
Motor Relay
Ventilation Fan High Relay
Ventilation Fan Low Relay
Ventilation Fan Slow Relay
Upper Cooling Motor Relay
Lower Cooling Motor Relay
Upper Heater Halogen 1 Relay
Upper Heater Halogen 2 Relay
Lower Heater
Relay
Convection Heater
Relay
High Voltage
Relay Enable Not Closing
Check voltage between Relay Board CN01 pins 4
and 28.
If 5 VDC is present, replace Relay Board.
If 5 VDC is not present, replace Smart Board.
Buzzer
When Buzzer should be on, check voltage between
Relay Board CN01 pins 3 and 4.
If 12 VDC is not present, the Smart Board is
not supplying the Buzzer operating voltage.
(See
troubleshooting section.)
Smart Board
If 12 VDC is present, replace Smart Board and
Relay Board.
Connector #
and Pin #
CN01-7
CN01-8
CN01-9
CN01-10
CN01-11
CN01-12
CN01-13
CN01-14
CN01-15
CN01-16
CN01-17
CN01-18
CN01-20
CN01-22
CN01-24
CN01-25
CN01-27
(Continued next page)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Advantium psa2201rAdvantium zsa2201r

Table of Contents