Table of Contents

Advertisement

cleARANces

cleARANces to coMBustIBles
Follow these instructions carefully to ensure safe installation. Failure
to follow instructions exactly can create a fire hazard.
the appliance cannot be installed on a carpet, tile or other
combustible material other than wood flooring. If installed on carpet
or vinyl flooring, the appliance shall be installed on a metal, wood
or noncombustible material panel extending full width and depth
of the appliance.
71" Minimum
Min. 4" 
From Either 
Side Wall
Figure 4 -
Clearances
Never obstruct or modify the air inlet or
outlet grilles (louvers). this may create a
fire hazard.
54D0700
11" Minimum
FP2248
mantel clearances
12" 
11"
Max.
Top of Exhaust
Louvers
FP48
FP093
Side of Fire-
place Opening
Figure 5 -
Mantel Clearances
BDV Series Direct Vent Gas Fireplace
Wall
12"
8"
6"
2"
7"
5"
3"
side View
FP2204
mantel clearances
Combustible
Material Area
1"
1 "
2 "
3"
4"
top View
FP2093
mantel side clearance
Stud
Insulation
Board
Standoff
FP04
Wall
2 "
45°
9