optIoNAl FAN BloWeR systeM
optIoNAl FAN/BloWeR systeM (Blotsc)
Installation Instructions
Wiring
1. Before installing the blower, wire the receptacle into an
electrical circuit. This should be done before framing the
fireplace. Wire with minimum 60° C wire in accordance with
prevailing codes.
. Remove the external junction box cover by removing the
screw from the left side of the outside firebox wall. Junction
box was installed at the factory.
3. The junction box cover has a factory in-
stalled "romex" style strain relief connector.
After connecting the wires, route the wire
leads through this connector. Refer to the
wiring diagram in Figure 53.
Before Installing the Blower
1. Always turn off the gas supply and allow
the unit to cool down before proceeding.
. Clean the inside of the firebox (wall and
floor), where the blower and wires will be
installed. Make sure the firebox wall and
floor are clean and dry before mounting the
blower.

Installing the Blower

1. Remove the lower access panel by pulling
up and away from unit.
. Remove glass frame by releasing the two
() latches (500 and 600 models have
three (3) latches) below the firebox open-
ing and lifting glass frame up and away
from unit.
3. Use the supplied Velcro on the blower and the magnetic strips to secure the blower to
the firebox wall and floor. Figure 54
4. Remove the tape from the back of the Velcro strips, slide the blower through lower ac-
cess door and position on the inside back firebox wall. The blower should be centered
with the rear blower discharge vent facing up (pointing up between the inside firebox
wall and inner combustion wall). The blower should be
flat against the firebox back wall. Figure 55
5. For 300 models, the air shield can be removed. Figure
54
6. Align the connector pin on the AC box to the control box
and gently push them together using the guiding block as
a guide. Figure 56
Keep wires away from combustion chamber
and blower wheel.
54D0700
Junction Box
Figure 53 -
Junction Box Wiring Diagram
Velcro Strips
top View
Front View
Figure 54 -
Velcro, Magnet Locations
KT553
velcro, magnets
12/08
Figure 55 -
Blower Location
BDV Series Direct Vent Gas Fireplace
FP1912

Junction box wiring

8/08
Magnets
KT553
side View
KT552
fan location
12/08
10V AC
60Hz
Factory Supplied
Not Supplied
Air Shield
(Remove from
300 Models)
Discharge
Vent
Fireplace
KT55
37