Hisense AMS-07UR4SNVT4 Service Manual page 96

Multi-split type air conditoner indoor and outdoor units
Table of Contents

Advertisement

8
.
C
H
E
C
K
I
N
G
C
8
.
C
H
E
C
K
I
N
G
C
3)Avoiding compressor running in reverse caused by connecting electrical wire incorrectly.
4)Warning! In case AC voltage is impressed to compressor, the compressor performance will
below because of its rotor magnetic force decreasing.
4. INDUCTANCE
Familiar error:
1)Sound abnormality
2)Insulation resistance disqualification.
5. STEP MOTOR
5
1
Test in resistance.
TOOL: Multimeter.
Test the resistance of winding. The stepper motor is fault if the resistance of winding 0(short
circuit)or∞(open circuit).
6. FUSE
Checking continuity of fuse on PCB ASS'Y.
1) Remove the PCB ASS'Y from the electrical component box. Then pull out the fuse from the
PCB ASS'Y (Fig.1)
2) Check for continuity by a multimeter as shown in Fig.2.
7.CAPACITOR
1) Remove the lead wires from the capacitor terminals, and then place a probe on the
O
M
P
O
N
E
N
T
S
O
M
P
O
N
E
N
T
S
4
2
Fuse
PCB Ass'Y
Fuse
Fig.2
Fig.1
91