Hisense AMS-07UR4SNVT4 Service Manual page 72

Multi-split type air conditoner indoor and outdoor units
Table of Contents

Advertisement

6
.
C
O
N
T
R
O
L
M
6
.
C
O
N
T
R
O
L
M
3.4 Sleep
1. In the heating, cooling or dehumidifying mode, press the "Sleep" button on the remote
controller to start or cancel the sleep function in turn, and at the same time the sleep icon on
the display screen will be on or off accordingly.
2. In the heating mode, the set temperature will decrease automatically after the sleep
function is started.
3. In the cooling mode, the set temperature will rise automatically after the sleep function is
started.
4. In default, the setting is to cancel the sleep function. Turning off the unit will also cancel
the sleep function.
3.5 High efficient run function
In Cool, Dehumidification, Fan mode, press the "HIGH POWER " to enter the refrigeration
mode, set the temperature automatically adjust to 18℃; the Fan speed is powerful speed;
frequency of high frequency operation.
In the heating mode, powerful function is invalid.
3.6 mute function (only for H1 wireless remote controller)
In the indoor machine operation mode,You may turn on mute function and turn off mute
function by mute key, The air conditioner will run by mute fan speed in mute mode
3.7 prevent cooling wind mode
In the heating-run, to prevent the indoor fan from blowing cold air, the indoor fan will stop
or run slowly until the coil is warmth.
3.8 blow waste heating and waste cooling function
The heating mode, remote shutdown, such as indoor heat exchanger temperature is
higher, the wind blowing out opportunities continue to run the waste heat, the wind guiding
vane is adjusted to the horizontal position.
Cool and dehumidification mode after the compressor close, indoor machine will continue
to set the speed of operation for a period of time.
Fan mode, compressor is shut off, the indoor fan immediately stop
3.9 automatically model
This model does not automatically model function, emergency button cannot set the
automatic mode of operation, can use the emergency button shutdown, remote setting the
automatic mode of indoor machine with remote signal.