Hisense AMS-07UR4SNVT4 Service Manual page 113

Multi-split type air conditoner indoor and outdoor units
Table of Contents

Advertisement

5
.
CONTROL
MODE
5
.
CONTROL
MODE
5-1. Major general technical parameters
5-1-1 Conditionings for operation: Ambient temperatures: (-7℃ - +43 ℃),
5-1-2 Remote receiver distance(front of the air conditioner): 8 m.
5-1-3 Remote receiver angle: Less than 60 degrees.
5-1-4 Temperature control accuracy: ±1℃.
5-1-5 Time error: Less than 1%.
5-2. Functions of the controller
5-2-1 Display panel
I. Control functions of the remote controller (See operating and installation
manual)
II. Display of the indoor unit
Information on the screen:
Displaying Scheme:
7-segment tube:Display set temperature or indoor temperature , and display
fault code in trouble indicating. An error code is displayed according to the
signal from the indoor CPU. The error code will flash for 5 seconds while
displayed.
Running LED:It is on during operation. It is flashing when the unit defrost.
TIMER LED:When the timer mode works, the LED will be lighted.
Sleep LED:When the sleep mode works, the LED will be lighted, and after 10s,
the LED will be off.
Compressor LED:It lights up when compressor is running.
Remote control receiver : This section receives signals from the remote
control.
5-3. Control function
5-3-1 Emergency switch
If the appliance under the Stand-by state, all the Operation Mode, Air
volume, Temperature Setting , Forced Cooling function will be restored as the
last time setting when you press on the "ON/OFF" button, but lost the Air flow
direction setting.
If the appliance was connected to the power at first time, it would operate in
the auto mode, It will keep in stand-by state if you press the "ON/OFF" button
during the normal operation.
When the appliance under the Stand-by state, press and hold the
emergency switch for 5 seconds, the buzzer rings for 1 times, and it will operate

Hide quick links: