5
.
CONTROL
MODE
5
.
CONTROL
MODE
the max setting temperature decrease is 3℃.
(5) When the appliance operate with Sleep mode, the indoor fan run in the
LOW setting, and the air flow direction same as the last setting and the
temperature and air flow direction can be adjusted by user. The Running
indicator will be flashed 10 times per 1 Hz frequency, then all the indicators turn
OFF except the Sleep light after 5 min elapse. Those indicators will be recovery
when the temperature or Time setting is adjusted, after the setting, the
indicators will be lit in 10 sec, then turn OFF.
5-3-5 Automatic run (SMART) mode
When the appliance operates at the smart, the air flow direction can be
adjusted.
(1) H/C appliance
a. When the setting temperature is 26℃, the appliance will be ran in the
Cool if the room temperature exceeds 26℃.
b. When the room temperature exceeds 23℃, but below 26℃, it will be ran
in the Dry mode(It will turn in Automatic setting After 3 min LOW air volume
running.).
c. When the room temperature exceeds 21℃, but below 23℃, it will be
operated in the Fan only, the air volume is set by LOW and the fan speed can be
adjusted
d. When the room temperature is not more than 21℃, it will be operated in
Heat mode, and the temperature is set to 22℃.
(2) Cool only appliance
a. When the room temperature exceeds 26℃, it will be ran in Cool mode,
and the temperature is set to 26℃.
b. When the room temperature exceeds 23℃, but not more than 26℃, it will
be operated in the Dry mode.
c. When the room temperature is not more than 23℃, it will be operated in
the Fan only, the air volume is set to LOW and the fan speed can be adjusted
After the appliance start the smart operation, the setting temperature can
be adjusted 2℃ or 7℃ (based on the remote mode)(the min accuracy is 1℃)
up and down base on the automatic temperature setting, also the presetting
temperature of PCB circuit.
In case of the specific operation selected, it could be re-select the other
modes after the compressor ceased for 5 min or the setting temperature
changed.
5-3-7 Cooling-run mode