PERFORMANCE
AMS-07/09/12UR4SG(NK/NM/VT/VQ)4
Stepper Motor
model
Voltage(DC)
Number of phase
Drive mode
Resistance per
phase
Temperature
range(℃)
I
O
N
S
I
O
N
S
AMS-07/09/12UR4SN
4
24BYJ48
12V
4
1-2phase excitation unipolar drive
300Ω±7%
-10℃~+40℃
16
PARAMETER
AMS-18UR4SV(
VG4/VL4/VT4/U
P4/UL4/UQ4/VQ
AMS-09/12UR4SPSC4
4/NT4/NK4/NM4
)
28BYJ48
24BYJ48XH6
1-2phase excitation
unipolar drive
200Ω±7%
-10℃~+40℃
AMV-12UR4SA
AMV-18UR4SA
35BYJ46-840
12V
12V
4
4
1-2phase
excitation
unipolar drive
100Ω±7%
-10℃~+40℃