Lowrance ELITE TI Installation Manual page 40

Hide thumbs Also See for ELITE TI:
Table of Contents

Advertisement

40
1.
Start with a full tank and run the engine as it would normally be
operated.
2.
After at least several liters (a few gallons) have been used, the
tank should be fully refilled, and the Set to full option selected.
3.
Select the Calibrate option.
4.
Set the actual amount used based on amount of fuel added
to the tank.
5.
Select OK to save settings. The Fuel K-Value should now show
a new value.
Note:
Ú
To calibrate multiple engines repeat the steps above,
one engine at a time. Alternatively, run all engines
simultaneously, and divide the Actual amount used by the
number of engines. This assumes reasonably even fuel
consumption on all engines.
Note:
The Calibrate option is only available when Set to
Ú
full is selected, and a Fuel Flow is connected and set up as
a source.
Note:
Ú
A maximum of 8 engines is supported using Fuel
Flow sensors.
Fuel Level
Fuel level configuration is available on the ELITE-7Ti only.
With the use of a Navico Fluid Level device connected to a suitable
tank level sensor, it is possible to measure the amount of fuel
remaining in any equipped tank. The number of tanks must be set
in Vessel Setup dialog, initiated from the Fuel setting options page,
to allow discrete tank assignment of the Fluid Level devices.