Air Shutter Adjustment

This appliance has an air shutter adjustment lever located behind the
lower door of the inserts face, directly above the gas valve (see Figures
17 and 18). The lever is linked to the primary air shutter on the main
burner. The air shutter regulates the amount of primary air the burner
receives and therefore how clean the insert burns. The air shutter should
only be adjusted by a qualified gas technician. The insert should burn for
about 15 minutes with the glass media installed before adjusting the air
shutter. More air will result in shorter flames and less color, less air will
result in bigger flames and more color. To adjust the air shutter, move
the adjustment lever toward or away from you using a screw driver or
needle nose pliers. (see Figures 17 and 18).
CAUTION: The air shutter should never be set so as to make
the tips of the flames sooty or create sooting on the viewing
glass, glass media, or firebox panels. If soot begins to form
after burning, the air shutter should be opened gradually until
the sooting condition stops. Gas quality and gas pressure may
vary, which can affect the burning characteristics of the insert.
See Shutter
SEE DETAIL
A
Adjustment Detail
(Figure 18)
SHUTTER ADJUSTMENT DETAIL
Figure 17
Pulling the adjustment lever toward you will open
the shutter, pushing it away will close the shutter.
Figure 18 - Shutter Adjustment Detail
DETAIL A
DETAIL A
SCALE 0.600
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Battery Backup - Battery Installation

This appliance is equipped with a battery backup system. It requires four
(4) "AA" batteries, not provided, to power the appliance (without the blower)
during a power outage. Install the batteries into the battery holder per
instructions in Figure 19.
Batteries, even if not used, will gradually drain over time. It is rec-
ommended to annually check the batteries for sufficient charge and
replace when necessary.
ON
BU RN ER
TO TA L
AU TO
CO MF OR
T
CO NT RO
L
PIL OT
Figure 19
INSTALLER INSTRUCTIONS - ATTACH SAFETY-IN-
OPERATION WARNING LABELS
It is required that the set of safety instruction labels that have been
furnished with the appliance be affixed to the operation and control
points of the appliance per the instructions on Page 7. It is the
installers responsibility to ensure these warnings are properly
affixed during installation. These warning labels are a critical
step in informing consumers of safe operation of this appliance.
SHUTTER ADJUSTMENT DETAIL
DETAIL A
Battery Holder
SCALE 0.600
Ensure Positive and Negative
ends of the battery are installed
as indicated in battery holder
+
-
AA Battery