PDT 7200 Series Product Reference Guide for Windows
Condition
Spare Battery Charge LED Terminal Charge LED
BLINKING Faulty battery.
Cradle Self Test
On power up, the cradles perform a self-test which checks the RAM and ROM. The
Communications LED flashes during the self-test. The Communications LED on the cradle
reveals the status as follows:
Communications LED Condition
Power up/Self-Test (7 flashes -> off)
LED flashing (8 flashes/second)
LED flashing slowly (4 flashes/second)
If the cradle fails self-test (RAM or ROM failure), power the cradle down and back up. If the
self-test fails again, call the Symbol Support Center for assistance.
Batteries
Primary power for the PDT 7200 is provided by a Lithium-Ion battery. The batteries operate
for 8 hours in typical operating environments, although battery life between charges varies
drastically depending on conditions, equipment options, and power demands.
If the battery is fully discharged and untouched for approximately one week, re-initialize the
battery. Refer to
Re-initializing the Battery Pack
Battery Life
To increase the Lithium battery life, use software controls to decrease power demands:
Turn off communication ports not used.
!
Turn off the backlight.
!
4-8
Table 4-1. Cradle LED Indications
Faulty battery.
Table 4-2. Cradle Power LED
on page 4-11.
®
CE
COM LED
Terminal is able to send and
receive data.
Status
No error in RAM or ROM
RAM test failure
ROM (CRC on flash) failure