Wall Switch Installation; Ipi System Wiring Diagram - Vermont Castings VFC24C Installation & Operating Instructions Manual

Vfc vent free fireplace system
Table of Contents

Advertisement

VFC Vent Free Fireplace System

WALL SWITCH INSTALLATION

The wall switch wire connection is located off the wire
harness coming out of the IPI Control Board. The label is
wired 'wall switch'. Connect the low voltage switch wires to
the two (2) terminals labeled "wall switch" from the control

IPI SYSTEM WIRING DIAGRAM

BLACK
RED
Figure 19 –
IPI System Wiring Diagram
Electrical connections should only be performed by a qualifi ed, licensed electrician. Main
power supply must be turned off before connecting fans to the main electrical power supply
or performing service.
20
ORANGE
YELLOW
BLACK
BROWN
ELECTRICAL INSTALLATION – IPI
board. Run wire to desired location on wall. Up to 50 feet
of 18 gauge wire may be used if necessary. Attach wires
to wall switch. Mount the wall switch in a junction box and
screw on cover. Figure 19
RED
RED
RED
BLACK
BLACK
RED
20308011

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vfc24lVfc32cVfc32l

Table of Contents