Section 3 − Specifications; Specifications; Volt-Ampere Curves - Miller Electric MARK VIII-2 Owner's Manual

Arc welding power source
Table of Contents

Advertisement

3-1. Specifications

Rated Welding
Rated Welding
Output For Main
Output For Main
Output For Each
Output For Each
Transformer
800 A @ 40 Volts DC,
100% Duty Cycle;
200 A @ 40 Volts DC,
1600 A @ 40 Volts DC,
60% Duty Cycle
25% Duty Cycle
*While idling

3-2. Volt-Ampere Curves

SECTION 3 − SPECIFICATIONS
Module
Max OCV DC
80
Amperes Input at Rated Load Output, 60 Hz,
Three-Phase
220 V
230 V
380 V
440 V
178
170
103
89
8*
8*
5*
4*
460 V
575 V
KVA
KW
85
68
68
48.6
4*
3.2*
3.18*
2.65*
The volt-ampere curves show the
minimum and maximum voltage
and amperage output capabilities of
each module. Curves of other set-
tings fall between the curves
shown.
ssb1.1* 10/91 − SB-083 110-C