Electrical Service Guide; Section 5 − Operation; Controls - Miller Electric MARK VIII-2 Owner's Manual

Arc welding power source
Table of Contents

Advertisement

4-11. Electrical Service Guide

Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Rating In Amperes
Min Input Conductor Size In AWG
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG
Reference: 2005 National Electrical Code (NEC)
1 Consult factory for circuit breaker applications.
2 "Time-Delay" fuses are UL class "RK5" .
3 "Normal Operating" (general purpose - no intentional delay) fuses are UL class "K5" (up to and including 60 amp), and UL class "H" ( 65 amp and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.

5-1. Controls

OM-218 Page 20
1
2
Time-Delay
Normal Operating
4
4
SECTION 5 − OPERATION
220
230
178
170
200
200
3
250
250
3/0
2/0
230
214
(70)
(65)
4
4
1
2
3
4
5
380
440
460
103
89
85
125
110
100
150
125
125
2
3
3
349
389
424
(106)
(118)
(129)
(169)
6
6
6
1
Remote Amperage Control
Switch
2
Module Supplementary
Protectors (See Section 6-2)
3
Amperage Adjustment Control
4
Power Switch
5
Pilot Light
ST-144 570-A
575
68
80
100
4
554
8