Installation and connection

Leveling the dryer

To ensure trouble-free operation, the
dryer must be perfectly level.
^ Compensate for floor irregularities by
turning the threaded feet in or out.
32
,
Ensure that is an air gap of at
least 10 mm between the underside
of the dryer and the floor. This air
gap must not be restricted by power
bars, high-nap carpets, etc.
Otherwise, sufficient air flow cannot
be guaranteed.

Ventilating the installation area

The air needed for drying is
extracted from the installation
space. You must therefore take
measures for sufficient room
ventilation, by opening windows for
instance.
Otherwise you can expect longer
running times and higher energy
consumption.