Metrologic MS9535 Installation And User Manual page 35

Wireless hand-held laser scanner
Hide thumbs Also See for MS9535:
Table of Contents

Advertisement

T
ROUBLESHOOTING
Symptoms
The unit is
transmitting
each character
twice
Everything
works except for
a couple of
characters
Power-up OK
and scans OK
but does not
communicate
properly to the
host
Power-up OK
and scans OK
but does not
communicate
properly to the
host
Power-up OK
and scans OK
but does not
communicate
properly to the
host
The host is
receiving data
but the data
does not look
correct
Characters are
being dropped
G
(
UIDE
CONTINUED
Possible Causes
Configuration is not
correct
These characters
may not be supported
by that country's key
look up table
Com port at the host
is not working or
configured properly
Cable not connected
to the proper com
port
Cable not connected
to the proper com
port
The cradle and host
may not be
configured for the
same interface
parameters
Inter-character delay
needs to be added to
the transmitted output
)
Solution
Increase interscan code delay
setting. Adjust whether the F0
break is transmitted. It may be
necessary to try this in both
settings.
Try operating the scanner in Alt
mode.
Check to make sure that the baud
rate and parity of the scanner and
the communication port match
and the program is looking for
"RS-232" data.
Check to make sure that the baud
rate and parity of the scanner and
the communication port match
and the program is looking for
"RS-232" data.
Check to make sure that the baud
rate and parity of the scanner and
the communication port match
and the program is looking for
"RS-232" data.
Check that the cradle and the host
are configured for the same
interface parameters
Add some inter-character delay to
the transmitted output