Recall Defaults
D

RS-232 Parameter - Hardware Handshaking

To prevent scanned information from being lost
during transmission, your host device may require
an RTS/CTS signal. When the RTS/CTS (Request
To Send/Clear To Send) is enabled, the scanner
will output an RTS signal and wait for a CTS
signal before any data is transmitted. The default
setting of RTS/CTS is disabled. If necessary, scan
the ENABLE RTS/CTS bar code.
** Character RTS/CTS
When this option is chosen, the scanner will
activate and deactivate its RTS signal on each
character that it transmits.
R
5
6
Message RTS/CTS
When this option is chosen, the scanner will activate
and deactivate its RTS signal on each message that it
transmits. This mode should normally be enabled for
Sanyo registers.
R
5
7

RS-232 Parameter - Software Handshaking

For control of the data transmission process, use ACK/NAK or XON/XOFF
instead of or in addition to the RTS/CTS hardware handshaking option.
Enable ACK/NAK
When this option is enabled, the scanner will not
scan again unless an ACK (ASCII 06H) is
received after transmission of a bar code. If an
S
H
2
NAK (ASCII 15H) is received, the scanner will
** Disable ACK/NAK
retransmit the bar code.
S
H
1
When this option is enabled, the scanner will stop
Enable XON/XOFF
transmission whenever an XOFF (ASCII 13H) is
received. Transmission will resume after an
S
H
4
XON (ASCII 11H) is received.
** Disable XON/XOFF
S
H
3
F
1
Enable RTS/CTS
H
H
1
** Disable RTS/CTS
H
H
2
11