Chapter 8. Schematic Diagram; Description Of Schematic Dia; Gram; Schematic Diagram - Sharp XG-PH70X Service Manual

Hide thumbs Also See for XG-PH70X:
Table of Contents

Advertisement

CHAPTER 8.
XG-PH70X

SCHEMATIC DIAGRAM

[1] DESCRIPTION OF SCHEMATIC DIA-

GRAM

1. VOLTAGE MEASUREMENT CONDITION:
1. Voltages at test points are measured at the supply voltage of AC
100V/CROSS 10V-240. Signals are fed by a color bar signal gener-
ator for servicing purpose and the above voltages are measured
with a 20k ohm/V tester.
2. INDICATION OF RESISTOR & CAPACITOR:
RESISTOR
1. he unit of resistance "Ω" is omitted.
(K=kΩ=1000 Ω, M=MΩ).
2. All resistors are ± 5%, unless otherwise noted.
(J=± 5%, F= ± 1%, D= ± 0.5%)
3. All resistors are 1/10W, unless otherwise noted.
4. All resistors are Carbon type, unless otherwise noted.
: Solid
: Cement
W
C
: Oxide Film
: Special
S
T
: Metal Coating
N
CAPACITOR
1. All capacitors are µF, unless otherwise noted.
(P=pF=µµF).
2. All capacitors are 50V, unless otherwise noted.
3. All capacitors are Ceramic type, unless otherwise noted.
(ML): Mylar
(TA): Tantalum
(PF): Polypro Film
(ST): Styrol
CAUTION:
This circuit diagram is original one, therefore there may be a
slight difference from yours.
SAFETY NOTES:
1. DISCONNECT THE AC PLUG FROM THE AC
OUTLET BEFORE REPLACING PARTS.
2. SEMICONDUCTOR HEAT SINKS SHOULD BE
REGARDED AS POTENTIAL SHOCK HAZARDS
WHEN THE CHASSIS IS OPERATING.
IMPORTANT SAFETY NOTICE:
PARTS MARKED WITH "
IMPORTANT FOR MAINTAINING THE SAFETY OF THE
SET. BE SURE TO REPLACE THESE PARTS WITH
SPECIFIED ONES FOR MAINTAINING THE SAFETY AND
PERFORMANCE OF THE SET.
" (
) ARE
XG-PH70X/XG-PH70X-N (1st. Edition)
Service Manual
8 – 1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xg-ph70x-n

Table of Contents