• Hardware Flow Control
• Delimiter
the end of transmission. The default is "1".
Flow control manages data flow between devi
processed e
fficiently. Too much data arriving before a device is prepared to
manage it causes lost o
r retransmitted data.
none, HW
The default value is "none".
Character The Character 1 and Character 2 allow the use to enter two ASCII
character (in hex format) that delimit the beginning and end of a message. Wh
a message with
both there delimiters is received at the serial port, the data
contained in the serial buffer is paced in an Ethernet packet and sent out the
Ethernet port.
For the defined period of time passed, the serial port stops data
Silent Time:
transmission and close the connection to remote host.
Drop Character: If the
incoming
packet will be dropped
The default value is "Disable"