Genie GTH-6622 Operator's Handbook Manual page 78

Table of Contents

Advertisement

D-3.9
CHECKING THE OIL LEVEL IN THE
TANK
DANGER
Fine jets of hydraulic oil under pressure can
penetrate the skin. Do not use your fingers, but a
piece of cardboard to detect oil leaks.
Check the hydraulic oil level (visually) through the
special level
fitted into the tank.
When necessary, add new oil through filler
CAUTION
Check the oil level with handler set to transfer position
(lowered boom and retracted telescopic element).
SERVICE INTERVAL
Running-in _________ Within the first
Ordinary ____________________ Every
If oil must be changed, proceed as follows:
1
Stop the machine on a level ground and make sure
the parking brake is engaged.
2
Release the pressure from the hydraulic circuit.
3
Place a container of suitable size under the drain
plug, placed in the lower part of the reservoir, and
collect any oil leaks.
4
Remove the drain plug and allow oil to flow out into
the container.
5
Remove the inspection cover of tank
6
Carefully wash the tank with Diesel oil and blow a
jet of compressed air.
7
Refit the drain plug and the inspection cover.
8
Add new oil by making sure that it matches the
recommended type indicated in paragraph D-5.2.2.
until it is level with
SERVICE INTERVAL
Running-in ____________________________ None
Ordinary ________________ Every
Handler with telescopic boom GTH-6622
.
10
hours
50
hours
.
.
1000
hours
Document 57.0005.8200 - 12/2005
MAINTENANCE
PROTECT THE
ENVIRONMENT
The handling and disposing of used oils can be
ruled by local or national regulations. Address to
authorised centres.