Top Vent or Rear Vent Configuration

This appliance is shipped in the rear vent configuration. To change to the top vent configuration, follow
the directions below.
NOTE: the vent configuration affects several aspects of installation (framing, maximum vent rise,
maximum vent run). Make sure the vent configuration is correct prior to installation. You may wish to
configure the diffuser when changing the vent configuration.

Converting the Fireplace to Top Vent Configuration

Remove and discard the
heat shield. Replace the 4
removed screws.
Remove the 4 screws securing the
intake cover plate. Place the screws
and cover plate aside.
© Travis Industries
Installation
(for qualified installers only)
NOTE: Use a magnetic-tipped
nutdriver on these screws - take
care to prevent the screws from
falling into the fireplace.
Remove the 4 screws securing the
outer flue assembly. Place the
screws and assembly aside.
4141208
Remove the 4 screws securing the
inner flue assembly. Place the
screws and assembly aside.
Remove and discard the
insulation found below the
large cover plate.