2
Listing and Code Approvals
A. Appliance Certification
Model:
Laboratory:
Report No:
Type:
Standard:
B. BTU & Efficiency Specifications
EPA Certification #: 571 4-1-03
EPA Certified Emissions: 3.1 grams per hour
*LHV Tested Efficiency: 77.6 %
**HHV Tested Efficiency: 71.8%
***EPA BTU Output: 12,100 to 58,800 / hr.
****Peak BTU/Hour Output: 92,400
Vent Size: 8 inches
Firebox Size: 3.4 cubic feet
Recommended Log Length: 24 inches
* * Weighted average LHV (Low Heating Value) efficiency using
Douglas Fir dimensional lumber and data collected during EPA
emission test. LHV assumes the moisture is already in a vapor
state so there is no loss in energy to vaporize.
****Weighted average HHV (High Heating Value) efficiency using
Douglas Fir dimensional lumber and data collected during EPA
emission test. HHV includes the energy required to vaporize the
water in the fuel.
***A range of BTU outputs based on EPA Default Efficiency and
the burn rates from the low and high EPA tests, using Douglas
Fir dimensional lumber.
****A peak BTU out of the appliance calculated using the maxi-
mum first hour burn rate from the High EPA Test and the BTU
content of cordwood (8600) times the efficiency.
The Quadra-Fire 7100FP meets the 2015 US Enviornmen-
tal Protection Agency's crib wood emission limits for wood
heaters sold after May 15, 2015.
This wood heater needs periodic inspection and repair for
proper operation. It is against federal regulations to operate
this wood heater in a manner inconsistent with operating
instructions in this manual.
6
7100FP
OMNI Test Laboratories, Inc.
061-S-41-2
Wood Fireplace
UL 127 and ULC S610-M87 and
(UM) 84-HUD, Manufactured
Home Approved.
Fuel Seasoned Cord Wood
Quadra-Fire • 7100 FP Owner's Manual • 433-3600 • Rev J • 09/21/15
C. Mobile Home Approved
• This appliance is approved for mobile home installa-
tions when not installed in a sleeping room and when
an outside combustion air inlet is provided.
• The structural integrity of the mobile home floor, ceil-
ing, and walls must be maintained.
• The appliance must be properly grounded to the frame
of the mobile home with #8 copper ground wire.
• Outside Air Kit must be installed in a mobile home in-
stallation.
D. Glass Specifications
This fireplace is equipped with 5mm ceramic glass. Replace
glass only with 5mm ceramic glass. Please contact your
dealer for replacement glass.
WARNING
Fire Risk.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be voided by,
the following actions:
• Installation and use of any damaged appliance.
• Modification of the appliance.
• Installation other than as instructed by Hearth & Home
Technologies.
• Installation and/or use of any component part not approved by
Hearth & Home Technologies.
• Operating appliance without fully assembling all components.
• Do NOT Overfire - If appliance or chimney connector glows,
you are overfiring.
Any such action that may cause a fire hazard.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
For assistance or additional information, consult a qualified
installer, service agency or your dealer.
NOTE: Hearth & Home Technologies, manufacturer of
this appliance, reserves the right to alter its products, their
specifications and/or price without notice.
Quadra-Fire is a registered trademark of Hearth & Home
Technologies.