QSC DPA4.2 User Manual page 18

Dpa amplifiers
Hide thumbs Also See for DPA4.2:
Table of Contents

Advertisement

Create New Preset from an Existing Preset
To create a preset from an existing preset, recall the preset with the desired output confi guration, modify the Input parameters, Output parameters,
then save the preset. In addition, you can save the preset as you are going thru the creation process.
Recall a Preset
HOME > PRESETS > PRESET RECALL (ENTER)
A Preset includes the output confi guration, input parameters, and loudspeaker profi les (DSP, load, and assignments). There are 20 factory presets
that can be recalled, but not overwritten. Factory presets F1: Confi g thru F9: Confi g contain output confi gurations only. Factory presets F10: thru F20:
contain the output confi gurations and basic DSP for the confi gurations. There are 50 user presets that can be recalled and overwritten.
Step 1 — Select Preset
F1: A B C D
F1: A B C D
M
A
M
Input
Sub
Step 2 — Confi rm Selection
F1: A B C D
F18: 3-Way
M
A+B
Press ENTER to confirm selection
Set up the Inputs
HOME > INPUTS > SENS (ENTER)
NOTE: Changes made to input levels are in real time.
Step 1 — Select Input Sensitivity
F1: A B C D
Input
TD-000434-00-A
B
M
C
M
D
LF
MF
HF
Full
M
M
C
D
Input
1
Sens
Gain (dB)
+4 dBu
0.0
Indicates more Presets
To select the Preset confi guration, press
The message at the bottom changes to: "Recalling Preset now..."
You may hear relays clicking!
After confi rming the
Sensitivity setting, you can
scroll to Gain and adjust it,
before moving to the next
Input.
18
Scroll to desired Preset
20 Factory, 50 User-defi ned
To confi rm the selection, press
Scroll to select (+14 or +4 dBu)
To confi rm selection, press
To move to the next input, press
Repeat this procedure for
remaining input channels
`
`
`
ENTER
`
ENTER
`
`
ENTER
`
SEL

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dpa4.5Dpa4.3

Table of Contents