Rear Panel And Xsync Assembly; Removal; Installation; Removing Rear Panel Xsync Assembly - Polaroid Digital Microscope Camera Repair Manual

Hide thumbs Also See for Digital Microscope Camera:
Table of Contents

Advertisement

DMC Repair Manual
Rear Panel and XSYNC Assembly (Figure 2-3)

Removal

1. Remove the bottom extrusion.
2. Remove the two (2) screws that secures SCSI connector J5 to the rear panel.
3. Remove the two (2) screws securing the rear panel to the top extrusion.
4. Gently pull off the rear panel from the top extrusion being careful not to break the XSYNC
soldered cable leads from the XSYNC assembly.
5. Disconnect the XSYNC cable leads from connector J4 on the back end board.
XSYNC Assembly
SCSI Connector
(J4)
Figure 2-3. Removing rear panel and XSYNC assembly

Installation

1. Reconnect the XSYNC cable to connector J4 on the back end board.
2. Position the rear panel onto the top extrusion being careful not to pinch or grimp the
XSYNC cable leads between the top extrusion and the rear panel.
3. Install and tighten the two (2) screws that secures the rear panel to the top extrusion.
4. Install and tighten the two (2) screws that secures SCSI connector J5 to the rear panel.
5. Install the bottom extrusion.
XSYNC Cable
Rear Panel
20
Parts Replacement
Top Extrusion

Advertisement

Table of Contents
loading

Table of Contents