iNsTallaTioN
Continued
We recommend that you install a sediment trap in
supply line as shown in Figure 22, page 16. Locate
sediment trap where it is within reach for cleaning.
Install in piping system between fuel supply and
heater. Locate sediment trap where trapped mat-
ter is not likely to freeze. A sediment trap traps
moisture and contaminants. This keeps them from
going into fireplace controls. If sediment trap is
not installed or is installed wrong, fireplace may
not run properly.
CONNECTING EQUIPMENT
SHUTOFF VALVE TO HEATER
CONTROL
Installation Items Needed
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not
provided)
1. Open lower louver (see Figure 23).
NOTICE: Most building codes
do not permit concealed gas
connections. A flexible gas line
is provided to allow accessibility
from the fireplace (see Figure 23).
The flexible gas supply line con-
nection to the equipment shutoff
valve should be accessible.
2. Route flexible gas line, included, from fire-
place control to equipment shutoff valve
through side access holes in outer casing.
3. Apply pipe joint sealant lightly to male threads
of gas connector attached to flexible gas line/
equipment shutoff valve (see Figure 24).
CAUTION: Avoid damage to
gas control. Hold gas control
with wrench when connecting it
to gas piping and/or fittings.
4. Check all gas connections for leaks (see
Checking Gas Connections). Feed flexible
gas line into fireplace. Make sure the entire
flexible gas line is in fireplace.
116658-01D
Lower Louver
Figure 23 - Flexible Gas Line Location
To Control
Valve
Flexible Gas Line
from Fireplace Gas
Regulator Provided
With Fireplace
Figure 24 - Attaching Flexible Gas Line
CHECKING GAS CONNECTIONS
WARNING: Test all gas piping
and connections, internal and
external to unit, for leaks after
installing or servicing. Correct
all leaks at once.
open flame to check for a leak.
Apply a noncorrosive leak detec-
tion fluid to all joints. bubbles
forming show a leak. Correct all
leaks at once.
nal regulator has been installed
between propane/LP supply and
fireplace. See guidelines under Con-
necting to Gas Supply, page 16.
www.desatech.com
PROPANE/LP
To External Regulator
NATURAL GAS
To Gas Supply
to Equipment Shutoff Valve
WARNING: Never use an
CAUTION: Make sure exter-
Flexible Gas Line
Equipment
Shutoff Valve
17