Easy Series
12.7

EN50131 Requirements

The Easy Series Intrusion Control Panel is designed to comply with EN50131-1 Security Grade
2, Environmental Class II.
Installation, Programming, and Maintenance
Installation: Refer to Section 2.2 Install System Components, page 13.
Programming: Refer to Section 5 Programming, page 37.
Testing: Refer to Section 8 System Test and Maintenance, page 61.
Maintenance: Refer to Section 8 System Test and Maintenance, page 61.
Power Supply (AC and Standby Battery)
AC Power Supply: Refer to Section 10.2 Control Center, page 75.
Standby Battery: Refer to Section 10.2 Control Center, page 75.
Automatic Inhibit
Intruder Alarm and Fault Signal or Message: Set Expert Programming Item Number 131 to a value between 1 and 3.
Refer to Section 5.2.2 System Programming Items, page 43for more information.
Authorization Code: Set Expert Programming Item Number 892 to a value between 3 and 8.
Refer to Section 5.2.8 Control Center Programming Items, page 55for more information.
Logical and Physical Keys
Minimum Number of Combinations per User:
Passcodes: 15,625 (passcode length must be six digits)
Tokens: 42,000,000,000
Key Fobs: 2,800,000,000,000,000
Method Used to Determine Number of Combinations:
Passcodes: Digits 1 to 5 are allowed. For a six-digit passcode, all combinations are allowed.
Tokens: 32 bits. All combinations are allowed.
Key Fobs: 56 bits (48 serialized during manufacturing, 8 remain static)
Operating Temperature Range
Refer to Environmental Considerations on Page 72.
Control Panel and Control Center Current Consumption
Control Panel: Refer to Section 10.1 Control Panel, page 72.
Control Center: Refer to Section 10.1 Control Panel, page 72.
Output Current Rating
Refer to Programmable Outputs on Page 72.
To comply with EN50131-1, set these programming items as follows:
Programming Item
Programming Key Auto Transfer
Entry Delay
Swinger Bypass Count
Restrict Installer Passcode
RPS Automatic Call In Frequency
Passcode Length
Bosch Security Systems, Inc.
Item Number Setting
123
Select Option 0
127
Set to 45 sec or less
131
Select Option 3
142
Select Option 1
224
Select Option 0
861
Set passcode length to six digits
System Reference Guide
Agency Approvals and Requirements | en 119
Section Starting
Page
Page 43
Page 49
Page 56
F01U087835 | 02 | 2008.10