Easy Series (ICP-EZM2) | Installer Guide | 4.0 Programming
4.3.7

Control Center Programming Items

Speech Configuration Items
Item
Programming Item
Number
880
Alarm Message
Minimum Repeat Time
883
"No Alarm Report
Sent" Announcement
884
"Cancel Report Sent"
Announcement
887
Time Format
Global Control Center Items
These programming items affect all control centers connected to the control panel.
To send a user fire, emergency (medical) or panic report, the appropriate control center button and report
must be enabled. Refer to Section 4.3.4 Report Routing Programming Items on page 43 to enable reports.
Check the appropriate box in the Easy Series User Guide (P/N: F01U025111) to identify which buttons are
enabled.
Item
Programming Item
Number
888
Fire Button Alarm
889
Medical Button Alarm
890
Panic Button Alarm
891
One Button Arming
892
Invalid Passcode
Attempt Limit
893
Control Center
Lockout Time
52
Description (Range)
Enter how long the control center waits between alarm message
announcements before repeating the message even if the control
center's proximity sensor detects motion (1 to 255 hrs).
0 = No announcement for aborted alarms.
1 = Control center announces "No alarm report sent" for aborted
alarms.
0 = No announcement for canceled alarms.
1 = Control center announces "Cancel report sent" for cancelled
alarms.
0 = Determined by voice module
1 = Always use 12-hr mode
2 = Always use 24-hr mode
Description (Range)
0 = Item disabled.
1 = Press and hold [1] for 2 sec to start a fire alarm.
0 = Item disabled.
1 = Press and hold [1] and [2] for 2 sec to start a medical alarm.
System announces medical alarm message once every minute
for five min.
0 = Item disabled.
1 = Press and hold [2] for 2 sec to start an audible panic alarm.
2 = Press and hold [2] for 2 sec to start a silent panic alarm.
0 = Token or passcode is required to turn the system on.
1 = Press [i] to start Exit Delay for the first available system-on
option. No token or passcode is needed.
Enter the number of times a user can enter an invalid passcode, or
present an invalid token, before the user is locked out (3 to 8).
Enter the number of minutes that a user is locked out when the
Invalid Passcode Attempt Limit is reached (1 to 30).
Bosch Security Systems, Inc. | 5/07 | F01U025147-01
Entry
12
1
1
0
Entry
0
0
0
0
3
3