Easy Series (ICP-EZM2) | Installer Guide | 4.0 Programming
Programming Item
Call Waiting Disable
Emergency Call Override
Number
Emergency Call Override
Number Delay
Auto Detect Pulse Dial
Phone Answer Ring Count
Bell Test
Default
= Country-specific default. Select this programming item to hear the updated default value.
42
Item
Description (Range)
Number
215
Enter a 3-digit string. Dial this first before dialing the premises
phone number.
* = [*][*]; # = [*][#]
Dialing a call waiting sequence on a non-call waiting phone
line prevents the system from successfully contacting the
central station.
216
Enter a 3-digit emergency number, such as 911. If a user
dials this number, the system waits the amount of time
entered in Expert Programming Item Number 217 before
sending reports.
217
Enter the amount of time the system waits before sending
reports if an emergency number is dialed (0 to 60 min).
218
0 = Tone dialing only
1 = Auto Detect Pulse or Tone
222
Enter the number of rings before the system answers an
incoming call (1 to 255 rings).
223
This programming item applies to all Intrusion output types
and to all arming modes.
0 = No closing ring-back or bell test
1 = Enabled
If closing reports are disabled, the outputs turn on for 1
sec at the end of Exit Delay.
If closing reports are enabled, the outputs turn on for 1
sec. when the control panel receives a closing report
acknowledgement from the central station.