Easy Series (ICP-EZM2) | Installer Guide | 4.0 Programming
4.3.5

Point Programming Items

Refer to the Point Programming Entry Tables, starting on page 47, for expert programming item numbers, default
values, and programming entry cells.
Programming Item
Point Type
Circuit Style
Include in Custom Protection
Cross Zone Enabled
Response Time
Wireless Detector Sensitivity
46
Description (Range)
Refer to Section 4.2.1 Points on page 31 for point type descriptions.
0 = Disabled
6 = Fire Instant
1 = Perimeter
7 = Silent Panic
2 = Interior
8 = Interior Walkthrough
3 = Perimeter Instant
9 = Perimeter Exit Cancel
4 = 24-Hour
11 = Momentary Keyswitch
5 = Fire Verified*
12 = Maintained Keyswitch
* This option is not available for wireless smoke detectors.
0 = Dual 2.2 kΩ alarm and tamper circuit
2 = Single 2.2 kΩ alarm circuit
0 = Point not included in Custom Protection
1 = Point included in Custom Protection
Regardless of which protection mode is selected, 24-Hour, Fire Verified, Fire
Instant, and Panic points always create alarm conditions if faulted.
0 = Cross zoning disabled
1 = Cross zoning enabled
Do not change this item number's setting unless Expert Programming Item
Number 124 = 1.
Refer to page 38 for more information.
Sets the point's response time in 50 ms increments (1 to 10).
The value entered is multiplied by 50. For example, 6 x 50 = 300 ms response
time.
Determines how long the detector must detect motion before generating an
alarm. The lower this level is set, the longer the detector must detect motion
before generating an alarm. This applies to the wireless motion detectors (PIR
and dual) and inertia detector. This item also determines the inertia detector's
pulse setting.
Motion Detector (PIR and dual)
0 = Standard
4 = Intermediate
Inertia Detector
Gross Attack Options
0 = Tap off, low sensitivity
1 = Tap off, low/medium sensitivity
2 = Tap off, medium/high sensitivity
3 = Tap off, high sensitivity
Minor Attack Options
8 = Tap on, 8 taps, low sensitivity
9 = Tap on, 8 taps, low/medium sensitivity
10 = Tap on, 8 taps, medium/high sensitivity
11 = Tap on, 8 taps, high sensitivity
12 = Tap on, 4 taps, low sensitivity
13 = Tap on, 4 taps, low/medium sensitivity
14 = Tap on, 4 taps, medium/high sensitivity
15 = Tap on, 4 taps, high sensitivity
Bosch Security Systems, Inc. | 5/07 | F01U025147-01