Anom-
Type of
Description
aly
anomaly
GbCU
Cycle
Cavity upper burner
paused
locked
N°300
GrCo
Stops
Grease collector valve
cleaning
opened
N°325
cycle
H2OC
Warning
H2O check.
N°329
The oven retry the
water check 3 times
every 10min. After that,
EH2O is shown
HdXX
Stops oven
Valves/pumps
(XX =
activations
01-26)
HdPP
Stops
Valves/pumps activa-
liquid
tions (ACS feedback)
N°265
cleaning
HFnI
Stops
Humidifier not working
humidifier
N°280/
281
Htd
Stops oven
Drain temperature
above safety limit
N°252
InuS
Stops oven
Inverter software ver-
sion (YODA board)
N°118
incompatible with
present UI SW version
LPIn
Stops
Boiler level sensor
cycle
problem
N°227
MCbM /
Stops oven
Lower inverter commu-
Fd13
nication problem
MCtM /
Stops the
Upper inverter commu-
FU13
oven
nication problem
N°201
Possible causes
• Air in gas supply;
• Gas supply is closed;
• Issue with the electric
supply of the burner
system;
• Burner system internal
failure;
Misuse
• Water tap is closed
• Water flow rate less than
1 l/min
• No signal feedback from
flowmeter
Diagnostic according to
error number (from 01 to 26)
displayed.
• Water missing;
• ISG circuit obstruction.
Possible lack of water in the
drain system.
Wrong software upload
(example: after replacing
ACU board)
• Humid lime shortcutting
boiler level sensors.
• Insulation issues with the
boiler level sensors
• Issue with the motor
inverter;
• Connection or electrical
issue.
• Issue with the motor
inverter;
• Connection or electrical
issue,
Actions
The oven will not operate until restoring the
burner functionality.
To recover the functionality:
• Switch the oven OFF/ON.
• If the error occurs at the cycle start, call
Service.
• If the error occurs after 5 ignition attempts:
1. check the gas supply main valve is open
2. reset the error and attempt new cycle
3. if the error persists, switch OFF/ON the
oven and attempt new cycle again;
4. if the error persists, call Service
Ensure to close the grease collector drain valve
before restarting the cleaning cycle.
• check water tap is open
• check water pressure is good
• If the problem persists for 30 min and EH2O
rises, call Service
Switch the oven OFF/ON;
If the error persists, follow instructions displayed.
• Switch OFF and ON the oven, if the error
persists, manually clean the oven cavity and
call Service.
The oven has detected a problem with the
humidifier (ISG). It could be possible to cook in
convection mode only.
Verify the water supply valve is fully open and the
water filler has no obstructions. Clean it if
needed.
If the problem persists, call Service.
• Check that the oven has water supply;
• Pour some fresh water on the bottom cavity
filter; pay attention, do not splash hot cavity
with cold water as it could damage the
machine.
• Wait for the alarm to blink off;
• If the problem persists, call Service.
Inverter software version (YODA board) incom-
patible with present UI SW version.
Call service
The oven can continue to operate in convection
or in ISG mode.
• There is a problem with the water level in the
boiler: run a cleaning program including the
rinse and descale cycle and use 2 tabs C25
only. (Follow the procedure as per Operating
Manual);
• If the problem persists, call Service.
Communication error with lower cavity motor
inverter.
• Try to switch the oven OFF/ON.
• If the problem persists, call Service.
Communication error with upper cavity motor
inverter.
• Try to switch the oven OFF/ON.
• If the problem persists, call Service.