Sign In
Upload
Manuals
Brands
Vaisala Manuals
Test Equipment
HUMICAP TMP1
User Manuals: Vaisala HUMICAP TMP1 Temperature Probe
Manuals and User Guides for Vaisala HUMICAP TMP1 Temperature Probe. We have
4
Vaisala HUMICAP TMP1 Temperature Probe manuals available for free PDF download: User Manual, Quick Manual
Vaisala HUMICAP TMP1 User Manual (96 pages)
compatible humidity and temperature probes
Brand:
Vaisala
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Table of Contents
3
About this Document
9
Version Information
9
Related Manuals
9
Table Document Versions (English)
9
Table 2 Related Manuals
9
Documentation Conventions
10
Trademarks
10
Product Overview
11
Probe Structure
11
Basic Features and Options
11
Figure Probe Parts
11
Output Parameters
12
Table 3 Availability of Output Parameters
12
Additional Features with Indigo 200 Series Transmitters
13
Safety
13
ESD Protection
14
Regulatory Compliances
14
FCC Part 15 Compliance Statement
14
Canada ICES-003 Compliance Statement
15
Installation
16
Figure 2 Example Installation
16
HMP3 Probe
17
Figure 3 HMP3 Probe Dimensions
17
HMP4 Probe
18
Figure 4 HMP4 Probe Dimensions
18
HMP5 Probe
19
Figure 5 HMP5 Probe Dimensions
19
Figure 6 Optional Mounting Flange 210696 Dimensions
19
HMP7 Probe
20
Figure 7 HMP7 Probe Dimensions
20
HMP8 Probe
21
Figure 8 HMP8 Probe Dimensions
21
Attaching Ball Valve Kit to Process
22
HMP9 Probe
23
Figure 9 HMP9 Probe Dimensions
23
Installing HMP9 through a Cable Gland
24
Figure 10 Installing HMP9 Probe Head through a Cable Gland
24
MMP8 Probe
25
Figure 11 MMP8 Dimensions
25
TMP1 Probe
26
Figure 12 TMP1 Probe Dimensions
26
Wiring
27
Figure 13 M12 5-Pin A-Coded Male Connector Pinout
27
Figure 14 RS-485 Wiring
27
Configuration with Insight Software
29
Vaisala Insight Software
29
Installing Driver for the USB Service Cable
29
Connecting to Insight Software
30
Configuration Options
31
Figure 15 Connecting Probe to Insight
31
Figure 16 HMP5 in Insight Software
32
Using Probe with Indigo Transmitters
33
Indigo 200 Series Transmitter Overview
33
Figure 17 HMP7 Attached to Indigo 200 Series Transmitter
33
Figure 18 HMP7 Attached to Indigo 200 Series Transmitter with a Cable
34
Attaching Probe to Indigo 200 Series Transmitter
35
Figure 19 Attaching the Probe to Indigo 200 Series Transmitter
35
Wireless Configuration Interface Overview
36
Connecting to Wireless Configuration Interface
36
Figure 20 Enabling and Accessing Wireless Configuration Interface
36
Logging in to Wireless Configuration Interface
37
Figure 21 Indigo Login View
37
Maintenance
38
Cleaning the Probe
38
Chemical Tolerance
38
Table 4 Suitability of Cleaning Agents
38
Changing the Probe Filter
39
Replacing the Humicapâ R2 Sensor
39
Figure 22 HMP3 Probe Head with Filter Removed
40
Calibration and Adjustment
41
Adjustment Points and Requirements
42
Adjusting Measurement with Insight Software
43
Adjusting Measurement with Indigo 200 Transmitter
44
Figure 23 Calibration Page in the Indigo 200 Wireless Configuration Interface
46
Troubleshooting
48
Problem Situations
48
Error Messages
48
Table 5 Troubleshooting Table
48
Technical Data
51
HMP3 Specifications
51
Table 6 Measurement Performance
51
Figure 24 HMP3 Humidity Measurement Accuracy as a Function of Temperature
52
Figure 25 HMP3 Temperature Measurement Accuracy over Full Range
52
Table 7 Operating Environment
52
Table 8 Inputs and Outputs
53
Table 9 Mechanical Specifications
53
HMP4 Specifications
54
Figure 26 HMP3 Probe Dimensions
54
Table 10 Measurement Performance
54
Figure 27 HMP4 Humidity Measurement Accuracy as a Function of Temperature
55
Figure 28 HMP4 Temperature Measurement Accuracy over Full Range
55
Table 11 Operating Environment
56
Table 12 Inputs and Outputs
56
Table 13 Mechanical Specifications
56
HMP5 Specifications
57
Figure 29 HMP4 Probe Dimensions
57
Table 14 Measurement Performance
57
Figure 30 HMP5 Humidity Measurement Accuracy as a Function of Temperature
58
Figure 31 HMP5 Temperature Measurement Accuracy over Full Range
58
Table 15 Operating Environment
59
Table 16 Inputs and Outputs
59
Table 17 Mechanical Specifications
59
HMP7 Specifications
60
Figure 32 HMP5 Probe Dimensions
60
Table 18 Measurement Performance
60
Figure 33 HMP7 Humidity Measurement Accuracy as Function of Temperature
61
Figure 34 HMP7 Temperature Measurement Accuracy over Full Range
61
Table 19 Operating Environment
62
Table 20 Inputs and Outputs
62
Table 21 Mechanical Specifications
62
HMP8 Specifications
63
Figure 35 HMP7 Probe Dimensions
63
Table 22 Measurement Performance
63
Figure 36 HMP8 Humidity Measurement Accuracy as a Function of Temperature
64
Figure 37 HMP8 Temperature Measurement Accuracy over Full Range
64
Table 23 Operating Environment
65
Table 24 Inputs and Outputs
65
Table 25 Mechanical Specifications
65
HMP9 Specifications
66
Figure 38 HMP8 Probe Dimensions
66
Figure 39 Optional Ball Valve Installation Kit Dimensions
66
Table 26 Measurement Performance
66
Table 27 Operating Environment
67
Table 28 Inputs and Outputs
68
Table 29 Mechanical Specifications
68
MMP8 Specifications
69
Figure 40 HMP9 Probe Dimensions
69
Table 30 Measurement Performance
69
Figure 41 a W Measurement Accuracy
70
Table 31 Operating Environment
70
Table 32 Inputs and Outputs
70
Figure 42 MMP8 Dimensions
71
Table 33 Mechanical Specifications
71
TMP1 Specifications
72
Figure 43 TMP1 Temperature Measurement Accuracy over Full Range
72
Table 34 Measurement Performance
72
Table 35 Operating Environment
72
Figure 44 TMP1 Probe Dimensions
73
Table 36 Inputs and Outputs
73
Table 37 Mechanical Specifications
73
Accessories and Spare Parts
74
Figure 45 Optional Duct Kit 215003 Dimensions
74
Table 38 Connection Cables
74
Table 39 Accessories
75
Table 40 Spare Parts
75
Table 41 Spare Parts
75
Table 42 Accessories
75
Table 43 Spare Parts
76
Table 44 Accessories
76
Table 45 Spare Parts
76
Table 46 Accessories
76
Table 47 Spare Parts
77
Table 48 Accessories
77
Table 49 Accessories
77
Table 50 Spare Parts
77
Table 51 Accessories
77
Appendix A: Modbus Reference
79
Default Communication Settings
79
Function Codes
79
Data Encoding
79
Table 52 Default Modbus Serial Communication Settings
79
Table 53 Modbus Function Codes
79
32-Bit Floating Point or Integer Format
80
16-Bit Integer Format
80
Modbus Registers
80
Table 54 16-Bit Signed Integer Format Details
80
Measurement Data Registers
81
Table 55 Floating Point Measurement Data Registers (Read-Only)
81
Table 56 Integer Measurement Data Registers (Read-Only)
82
Configuration Registers
84
Table 57 Modbus Configuration Data Registers (Writable)
84
Device Identification Objects
87
Status Registers
87
Table 58 Device Identification Objects
87
Table 59 Modbus Status Data Registers (Read-Only)
87
Table 60 Error Codes in Register 0203
88
Test Value Registers
89
Table 61 Modbus Test Registers (Read-Only)
89
Modbus Communication Examples
90
Online Store
93
Warranty
93
Technical Support
93
Recycling
93
Advertisement
Vaisala HUMICAP TMP1 User Manual (60 pages)
Vaisala HUMICAP Humidity and Temperature Probes
Brand:
Vaisala
| Category:
Test Equipment
| Size: 2 MB
Table of Contents
Table of Contents
3
1 About this Document
7
Version Information
7
Related Manuals
7
Documentation Conventions
7
Table Document Versions
7
Table 2 Related Manuals
7
Trademarks
8
2 Product Overview
9
Probe Structure
9
Basic Features and Options
9
Figure Probe Parts
9
Additional Features with Indigo Transmitters
10
Safety
10
ESD Protection
11
HMP4 Probe
11
HMP5 Probe
11
Figure 2 HMP4 Probe Head Dimensions
11
Figure 3 HMP5 Probe Head Dimensions
11
HMP7 Probe
12
Figure 4 Optional Mounting Flange 210696 Dimensions
12
Figure 5 HMP7 Probe Head Dimensions
12
HMP8 Probe
13
Figure 6 HMP8 Probe Head Dimensions
13
Figure 7 Optional Ball Valve Installation Kit Dimensions
13
TMP1 Probe
14
Figure 8 TMP1 Probe Head Dimensions
14
3 Installation
15
Figure 9 Example Installation of HMP8 Model
15
Probe Body Dimensions and Pinout
16
Figure 10 Probe Body
16
4 Configuration with Insight Software
17
Vaisala Insight Software
17
Connecting to Insight Software
17
Figure 11 Connecting Probe to Insight
17
Configuration Options
18
Figure 12 HMP5 in Insight Software
18
5 Using Probe with Indigo Transmitters
19
Indigo Overview
19
Figure 13 HMP7 Attached to Indigo 200 Transmitter
19
Figure 14 HMP7 Attached to Indigo 200 Transmitter with a Cable
20
Attaching Probes to Indigo Transmitters
21
Figure 15 Attaching the Probe to Indigo 200 Series
21
Wireless Configuration Interface Overview
22
Connecting to Wireless Configuration Interface
22
Logging in to Wireless Configuration Interface
22
Figure 16 Enabling and Accessing Indigo's Wireless Configuration Interface
22
Figure 17 Indigo Login View
22
6 Maintenance
24
Cleaning the Probe
24
Chemical Tolerance
24
Table 3 Suitability of Cleaning Agents
24
Changing the Probe Filter
25
Calibration and Adjustment
25
Adjustment Points and Requirements
26
Adjusting Measurement Using Insight Software
26
7 Technical Data
28
HMP4 Specifications
28
Figure 18 HMP4 Humidity Measurement Accuracy as a Function of Temperature (Including Non-Linearity and Repeatability)
28
Table 4 Measurement Performance
28
Figure 19 HMP4 Temperature Measurement Accuracy over Full Range (Including Non-Linearity and Repeatability)
29
Table 5 si Traceable Calibration
29
Table 6 Operating Environment
29
HMP5 Specifications
30
Table 7 Inputs and Outputs
30
Table 8 Mechanical Specifications
30
Table 9 Measurement Performance
30
Figure 20 HMP5 Humidity Measurement Accuracy as a Function of Temperature (Including Non-Linearity and Repeatability)
31
Figure 21 HMP5 Temperature Measurement Accuracy over Full Range (Including Non-Linearity and Repeatability)
32
Table 10 si Traceable Calibration
32
Table 11 Operating Environment
32
Table 12 Inputs and Outputs
32
HMP7 Specifications
33
Table 13 Mechanical Specifications
33
Table 14 Measurement Performance
33
Figure 22 HMP7 Humidity Measurement Accuracy as Function of Temperature (Including Non-Linearity and Repeatability)
34
Figure 23 HMP7 Temperature Measurement Accuracy over Full Range (Including Non-Linearity and Repeatability)
34
Table 15 si Traceable Calibration
35
Table 16 Operating Environment
35
Table 17 Inputs and Outputs
35
Table 18 Mechanical Specifications
35
HMP8 Specifications
36
Table 19 Measurement Performance
36
Figure 24 HMP8 Humidity Measurement Accuracy as a Function of Temperature (Including Non-Linearity and Repeatability)
37
Figure 25 HMP8 Temperature Measurement Accuracy over Full Range (Including Non-Linearity and Repeatability)
37
Table 20 si Traceable Calibration
37
Table 21 Operating Environment
38
Table 22 Inputs and Outputs
38
Table 23 Mechanical Specifications
38
TMP1 Specifications
39
Figure 26 TMP1 Temperature Measurement Accuracy over Full Range (Including Non-Linearity and Repeatability)
39
Table 24 Measurement Performance
39
Table 25 si Traceable Calibration
39
Table 26 Operating Environment
39
Table 27 Inputs and Outputs
40
Table 28 Mechanical Specifications
40
Dimensions
41
Figure 27 Probe Body Dimensions
41
Figure 28 HMP4 Probe Head Dimensions
41
Figure 29 HMP5 Probe Head Dimensions
41
Figure 30 HMP7 Probe Head Dimensions
41
Figure 31 HMP8 Probe Head Dimensions
42
Figure 32 TMP1 Probe Head Dimensions
42
Figure 33 Optional Duct Kit 215003 Dimensions
42
Spare Parts and Accessories
43
Figure 34 Optional Ball Valve Installation Kit Dimensions
43
Table 29 Accessories
43
Table 30 Accessories
44
Table 31 Accessories
45
Table 32 Accessories
46
Table 33 Accessories
47
Appendix A: Modbus Reference
48
Default Communication Settings
48
Function Codes
48
Data Encoding
48
Table 34 Default Modbus Serial Communication Settings
48
Table 35 Modbus Function Codes
48
16-Bit Integer Format
49
32-Bit Floating Point or Integer Format
49
Table 36 16-Bit Signed Integer Format Details
49
Modbus Registers
50
Measurement Data Registers
50
Table 37 Modbus Measurement Data Registers (Read-Only)
50
A.4 Modbus Registers
50
Configuration Registers
52
Table 38 Modbus Configuration Data Registers (Writable)
52
A.4.2 Configuration Registers
52
Device Identification Objects
54
Table 39 Device Identification Objects
54
Test Value Registers
55
Table 40 Modbus Test Registers (Read-Only)
55
Modbus Communication Examples
56
Online Store
59
Warranty
59
Technical Support
59
Recycling
59
Vaisala HUMICAP TMP1 Quick Manual (47 pages)
Vaisala Indigo Compatible Humidity and Temperature Probes
Brand:
Vaisala
| Category:
Accessories
| Size: 0 MB
Table of Contents
English
5
English
2
Table of Contents
5
Product Overview
6
Probe Structure
6
Basic Features and Options
6
Installation
7
HMP4 Probe
8
HMP5 Probe
9
HMP7 Probe
10
HMP8 Probe
11
Attaching Ball Valve Kit to Process
12
HMP9 Probe
14
Installing HMP9 through a Cable Gland
15
TMP1 Probe
16
Connector Pinout
17
Attaching Probes to Indigo Transmitters
18
Vaisala Insight Software
19
Connecting to Insight Software
19
Modbus
20
Default Communication Settings
20
Measurement Data Registers
20
Configuration Registers
21
Test Value Registers
22
Technical Support
23
More Information
23
Warranty
23
Recycling
23
日本語
25
プローブ構造
26
基本機能とオプション
26
製品概要
26
取り付け
27
Hmp4 プローブ
28
Hmp5 プローブ
29
Hmp7 プローブ
30
Hmp8 プローブ
31
プロセスへのボールバルブキットの取り付け
32
Hmp9 プローブ
34
ケーブルグランドからの Hmp9 の取り付け
35
Tmp1 プローブ
36
コネクターのピン配列
37
プローブの Indigo 変換器への取り付け
38
Insight ソフトウェアへの接続
39
Vaisala Insight ソフトウェア
39
Modbus
40
計測データレジスター
40
通信の初期設定
40
設定レジスター
41
テスト値レジスター
42
リサイクル
43
Regulatory Compliances
45
技術サポート
43
Advertisement
Vaisala HUMICAP TMP1 Quick Manual (30 pages)
Humidity and Temperature Probes
Brand:
Vaisala
| Category:
Measuring Instruments
| Size: 6 MB
Table of Contents
Product Overview
5
HMP4 Probe
6
HMP5 Probe
6
Attaching Probes to Indigo Transmitters
10
Installation
11
Vaisala Insight Software
12
Connecting to Insight Software
12
Configuration Registers
14
プローブの Indigo 変換器への取り付け
22
Vaisala Insight ソフトウェア
24
Insight ソフトウェアへの接続
24
Advertisement
Related Products
Vaisala HUMICAP HMP155
Vaisala HUMICAP HM44
Vaisala HUMICAP HMP41
Vaisala HUMICAP HMP45
Vaisala HUMICAP HMP46
Vaisala HUMICAP HMP4
Vaisala HUMICAP HMP5
Vaisala HUMICAP HMP8
Vaisala HUMICAP TMW93
Vaisala TMD62
Vaisala Categories
Transmitter
Measuring Instruments
Accessories
Weather Station
Test Equipment
More Vaisala Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL