Rosemount 3051S Series Reference Manual (190 pages)
MultiVariable Transmitter
Brand:
Rosemount
| Category:
Measuring Instruments
| Size: 22 MB
Table of Contents
Table of Contents
3
Section 1 Introduction
9
Using this Manual
9
Product Recycling/Disposal
10
Overview
11
Safety Messages
12
Engineering Assistant Installation
12
Engineering Assistant Version 6.3 or Later
12
Installation and Initial Setup
13
Flow Configuration
15
Rosemount 3051SMV Engineering Assistant 6.3 or Later
15
Basic Navigation Overview
16
Launching Engineering Assistant
17
Preferences
17
Fluid Selection for Database Liquid/Gas
18
Fluid Properties
21
Primary Element Selection
21
Save/Send
23
Other Fluid Configurations
26
Basic Device Configuration
32
Detailed Device Configuration
35
Model Identification
35
Alarm and Saturation
35
Variable Mapping
39
LCD Display
40
Communication Setup
41
Burst Mode
41
Materials of Construction
43
Flow Configuration Parameters
44
Variable Configuration
46
Flow Rate
46
Energy Rate
52
Totalizer
57
Differential Pressure
60
Static Pressure
61
Process Temperature
62
Module Temperature
63
Analog Output
64
Menu Trees and Field Communicator Fast Keys
65
Field Communicator Fast Keys
70
Overview
73
Safety Messages
73
Installation Considerations
75
General
75
Mechanical
75
Environmental
75
Installation Procedures
75
Configure Security (Write Protect)
75
Configure Alarm Direction
76
Mounting Considerations
76
Mount the Transmitter
78
Mounting Brackets
79
Process Connections
81
Connect Wiring and Power up
83
Conduit Electrical Connector Wiring (Option GE or GM)
87
Grounding
87
Rosemount 305 and 304 Manifolds
88
Rosemount 305 Integral Manifold Installation Procedure
89
Rosemount 304 Conventional Manifold Installation Procedure
89
Manifold Operation
89
Overview
95
Safety Messages
96
Transmitter Calibration
97
Calibration Overview
97
Sensor Trim Overview
98
Differential Pressure Sensor Calibration
98
Static Pressure Sensor Calibration
100
Process Temperature Sensor Calibration
101
Analog Calibration
103
Transmitter Functional Tests
104
Flow/Energy Calculation Verification (Test Calculation)
105
Configuring Fixed Process Variables
105
Analog Output Loop Test
105
Process Variables
106
Process Variable Tabs
106
All Variables Tab
107
Field Upgrades and Replacements
107
Disassembly Considerations
107
Housing Assembly Including Feature Board Electronics
108
Terminal Block
110
LCD Display
111
Flange and Drain Vent
111
Supermodule Assembly
113
Overview
115
Device Diagnostics
115
HART Host Diagnostics
115
LCD Display Diagnostics
115
Error Messages
115
Measurement Quality and Limit Status
120
Engineering Assistant Communication Troubleshooting
121
Measurement Troubleshooting
122
Service Support
125
Safety Instrumented Systems (SIS) Certification
127
Rosemount 3051SMV Safety Certified Identification
127
Installation in SIS Applications
127
Configuring in SIS Applications
128
Damping
128
Alarm and Saturation Levels
128
Rosemount 3051SMV SIS Operation and Maintenance
129
Proof Test
129
Partial Proof Test
129
Comprehensive Proof Test
130
Inspection
130
Visual Inspection
130
Special Tools
130
Product Repair
130
Rosemount 3051SMV SIS Reference
130
Failure Rate Data
130
Failure Values
130
Product Life
131
Specifications
133
Performance Specifications
133
A.1 Specifications
133
Specifications and Reference Data
134
Functional Specifications
137
A.1.2 Functional Specifications
137
Power Supply
138
Physical Specifications
140
Electrical Connections
140
A.2 Dimensional Drawings
143
Dimensional Drawings
143
Ordering Information
146
Rosemount 3051S Multivariable Transmitter
146
A.3 Ordering Information
146
Rosemount 300SMV Housing Kit
152
Accessories
155
Rosemount Engineering Assistant (EA) Software Packages
155
A.4 Accessories
155
A.5 Spare Parts
158
Spare Parts
158
European Directive Information
163
Ordinary Location Certification
163
Installing Equipment in North America
163
Usa
163
B.5 Canada
164
Canada
164
Europe
164
B.7 International
165
International
165
B.8 Brazil
166
Brazil
166
B.9 China
167
China
167
B.10EAC - Belarus, Kazakhstan, Russia
168
EAC - Belarus, Kazakhstan, Russia
168
B.11Japan
169
B.12Republic of Korea
169
B.13Combinations
169
B.14Additional Certifications
169
Japan
169
Republic of Korea
169
Combinations
169
Additional Certifications
169
B.15Installation Drawings
170
Installation Drawings
170
Advertisement
Rosemount 3051S Series Reference Manual (166 pages)
Pressure, Level, and Flow Solutions with IEC 62951 (WirelessHART ) Protocol
Brand:
Rosemount
| Category:
Measuring Instruments
| Size: 5 MB
Table of Contents
Table of Contents
5
1 Section 1: Introduction
9
Using this Manual
9
Models Covered
10
Service Support
11
Product Recycling/Disposal
12
2 Section 2: Configuration
13
Overview
13
Safety Messages
13
Warnings ()
14
System Readiness
14
Confirm Correct Device Driver
14
Required Bench Top Configuration
15
Connection Diagrams
15
Device Network Configuration
16
Join Device to Network
16
Configure Update Rate
17
Remove Power Module
17
Review Configuration Data
18
Review Pressure Information
18
Review Device and Sensor Information
19
Review Radio Information
20
Check Output
20
Operating Parameters
20
Basic Setup
21
Set Process Variable Unit
21
Set Transfer Function
22
Damping
23
Write Protect
23
LCD Display
24
LCD Display Configuration
24
Detailed Setup
25
1Configure Process Alarms
25
2Sensor Temperature Unit
26
3Scaled Variable Configuration
26
4Re-Mapping Device Variables
30
Diagnostics and Service
31
1Master Reset
31
2Join Status
32
3Number of Available Neighbors
32
Advanced Functions for HART Protocol
33
1Saving, Recalling, and Cloning Configuration Data
33
3 Section 3: Installation
35
Overview
35
Safety Messages
35
Warnings ()
36
Considerations
37
General
37
Wireless
37
Mechanical
38
Environmental
38
Installation Procedures
40
Mount the Transmitter
40
Process Connections
46
Consider Housing Rotation
47
Grounding
47
High Gain, Remote Antenna (Optional)
47
Power Module Installation
48
Installing the LCD Display
48
Rosemount 304, 305 and 306 Integral Manifolds
49
Rosemount 305 Integral Manifold Installation Procedure
50
Rosemount 306 Integral Manifold Installation Procedure
50
Rosemount 304 Conventional Manifold Installation Procedure
51
Manifold Operation
51
4Section 4: Commissioning
55
Safety Messages
55
Warnings ()
55
Network Status
56
Verify Operation
56
Troubleshooting
58
5Section 5: Operation and Maintenance
59
Overview
59
Calibration
59
Sensor Trim Overview
60
Zero Trim
61
Sensor Trim
61
Line Pressure Effect (Range 2 and Range 3)
62
Compensating for Line Pressure (Range 4 and Range 5)
62
LCD Screen Messages
65
Startup Screen Sequence
65
Diagnostic Button Screen Sequence
67
Network Diagnostic Status Screens
68
Device Diagnostic Screens
71
6 Section 6: Troubleshooting
75
Overview
75
Safety Messages
75
Warnings ()
76
Disassembly Procedures
80
Remove from Service
80
Remove Terminal Block
80
Removing the Feature Assembly and the Supermodule from the Housing73
81
Reassembly Procedures
82
Attach the Supermodule to the Wireless Housing
82
Install the Terminal Block
82
Reassemble the Process Flange
83
Aappendix A: Specifications and
85
Specifications
85
Performance Specifications
85
A.1 Specifications
85
Functional Specifications
90
A.1.2 Functional Specifications
90
Physical Specifications
95
A.1.3 Physical Specifications
95
Power Module
97
Dimensional Drawings
100
A.2 Dimensional Drawings
100
Ordering Information
102
A.3 Ordering Information
102
B.1 Wireless Certifications
147
B.1.5 Hazardous Locations Certifications
149
Appendix C: High Gain Remote Antenna Option
151
Safety Messages
151
Functional Specifications
152
C.2 Functional Specifications
152
Installation Considerations
153
Transient / Lightning Considerations
153
C.3 Installation Considerations
153
Dimensional Drawings
154
C.5 Dimensional Drawings
154
Installation Steps
155
C.6 Installation Steps
155
D.1 Field Communicator Menu Trees
159
Rosemount 3051S Series Quick Installation Manual (46 pages)
MultiVariable Transmitter
Brand:
Rosemount
| Category:
Transmitter
| Size: 3 MB
Table of Contents
Power Supply
12
Table of Contents
30
Function Fast Key Sequence
31
Absolute Pressure Reading and Status
32
Absolute Pressure Sensor Limits
32
Absolute Pressure Units
32
Alarm and Saturation Level Configuration
32
Alarm and Saturation Levels
32
Analog Output Trim Options
32
Burst Mode Setup
32
Burst Mode Options
32
Callendar-Van Dusen Sensor Matching
32
Damping
32
Differential Pressure Zero Trim
34
Hazardous Locations Certifications
36
Advertisement
Rosemount 3051S Series Quick Start Manual (22 pages)
Pressure Transmitter & Flowmeter with WirelessHART Protocol
Brand:
Rosemount
| Category:
Transmitter
| Size: 4 MB
Table of Contents
Table of Contents
2
Wireless Considerations
3
Mount the Transmitter
4
Connect the Power Module
9
Trim the Transmitter
10
Close the Housing
10
Verify Operation
10
Troubleshooting
12
Reference Information
13
Product Certifications
14
Advertisement
Related Products
Rosemount 3051
Rosemount 3051CF Series
Rosemount 3051SF Series
Rosemount 3051SMV
Rosemount 3095MF Series
Rosemount 3144P
Rosemount 3107
Rosemount 3108
Rosemount 3144
Rosemount 3051SFA
Rosemount Categories
Measuring Instruments
Transmitter
Accessories
Analytical Instruments
Touch Panel
More Rosemount Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL