Sign In
Upload
Manuals
Brands
Rosemount Manuals
Transmitter
3108
Rosemount 3108 Manuals
Manuals and User Guides for Rosemount 3108. We have
2
Rosemount 3108 manuals available for free PDF download: Reference Manual, Technical Note
Rosemount 3108 Reference Manual (148 pages)
Flow Transmitter
Brand:
Rosemount
| Category:
Transmitter
| Size: 11 MB
Table of Contents
Table of Contents
5
1 Section 1: Introduction
11
Safety Messages
11
Manual Overview
12
Service Support
12
Product Recycling/Disposal
12
2 Section 2: Transmitter Overview
13
Introduction to the Transmitters
13
Theory of Operation
14
Components of the Transmitter
14
System Architecture
15
3 Section 3: Installation
17
Safety Messages
17
Considerations before Installation
18
Safety Considerations
18
Environmental Considerations
19
Mechanical Installation
19
Consider Liquid Surface Conditions
21
Consider In-Tank Effects
21
Mounting the Transmitter above the Liquid Surface
21
Open Channel Flow Installations
22
Electrical Installation
26
Connecting the Transmitter
26
Remote Temperature Sensor (on 3108 Only)
27
Wiring to Allow HART Communication
28
Lightning / Surge Protection and Other Loop Devices
28
4 Section 4: Configuration
29
Overview
29
Command Parameters
30
Base Units
30
Set as Empty
31
Present Depth
32
Learn False Echo
33
Auto Tank Map
34
Simulation of PV
35
Restart Device
37
Load Defaults
38
Simulate Current Output
39
Trim 4Ma / Trim 20Ma
40
Configuration Parameters
41
Message (P000)
41
Tag (P001)
42
Descriptor (P002)
43
Final Assembly Number (P004)
44
Serial Number (P005)
45
Bottom Reference (P010)
45
Upper Blanking (P023)
48
Lower Blanking (P063)
49
Distance Offset (P060)
50
Level Offset (P069)
51
Tank Shape / Non-Linear Profile (P011)
52
Contents (Volume) Measurement
53
Flow Measurement
58
Primary Variable Units (P012)
61
Scale Factor / K-Factor (P013)
62
Profile Height / Power Factor (P014)
63
Profile Points 1 to 10 (P030 to P039)
65
Upper Range Value (P015)
66
Lower Range Value (P016)
67
Damping (P020)
68
Lost Echo Delay (P021)
69
Lost Echo Action (P022)
70
Speed of Sound (P024)
72
Temperature (P025)
73
Set Threshold (P026)
74
Transmit Power Control (P040)
76
Pulse Repeat (P041)
77
Echoes Needed (P042)
77
Threshold 1 Time (P043)
78
Threshold 1 Size (P048)
79
Target Pulses (P044)
81
Target Frequency (P045)
82
Spike Rejection (P049)
83
False Echo Data (P081 to P088)
84
Clear False Echoes (P089)
85
Transducer Material (P970)
86
Poll Address (D951)
87
Maximum Temperature (P046)
88
Minimum Temperature (P047)
88
Date (P003)
89
5 Section 5: Service and Troubleshooting
91
Safety Messages
91
Servicing
92
Power Failure
92
False Echoes under Certain Ambient Operating Conditions
92
Monitoring and Diagnostic Parameters
93
Process Value / Primary Variable (PV) (D900)
94
Level / Secondary Variable (SV) (D901)
95
Distance / Tertiary Variable (TV) (D902)
96
Temperature / Fourth Variable (FV) (D903)
97
Of Current Output (D905)
98
Current Output (D906)
99
Distance (D910)
100
Echo Size (D911)
101
Echo Success (D912)
102
Target Echoes (D913)
103
Speed of Sound (D914)
104
Temperature for Sos Calculation (D915)
104
Frequency (D916)
106
Threshold in Use (D917)
107
Pulses in Use (D918)
108
Transmit Power (D919)
109
Model Code (D949)
110
Hardware Rev. (D952)
111
Software Revision (D953)
112
Manufacturer (D960)
113
Unique Device ID (D961)
114
HART Revision (D962)
115
Transmitter Specific Command Rev. (D963)
116
Preambles (D964)
117
Transmitter Flags (D965)
118
Primary Variable Trend
118
Temperature Trend
119
Distance and Echo Size Trend
119
Specifications
121
General
121
Measuring Performance
121
Configuration
122
Electrical
122
Materials of Construction
123
Mechanical
123
Measuring
123
Environment
123
Temperature and Pressure Ratings
124
Load Limitations
124
Dimensional Drawings
125
Ordering Information
128
Spare Parts and Accessories
130
Safety Messages
131
Approved Manufacturing Locations
132
European Union Directive Information
132
MCERTS Certification
132
Hazardous Locations Certifications
132
American and Canadian Approvals
132
European Certifications
133
Rest of the World Certifications
133
Approval Drawings
135
Advertisement
Rosemount 3108 Technical Note (8 pages)
Ultrasonic Transmitters
Brand:
Rosemount
| Category:
Transmitter
| Size: 0 MB
Table of Contents
Measurement Range
2
Process Connection
2
Electrical Connections
2
System Integration
3
Installation Best Practices
4
General Considerations
4
Installation Considerations
4
Environmental Considerations
5
Mounting the Transmitter above the Liquid Surface
5
Open Channel Flow Installations
6
Advertisement
Related Products
Rosemount 3144P
Rosemount 3152
Rosemount 3153
Rosemount 3154
Rosemount 3107
Rosemount 3144
Rosemount 3051
Rosemount 3051SMV
Rosemount 3244MV
Rosemount 3051SF Series
Rosemount Categories
Measuring Instruments
Transmitter
Accessories
Analytical Instruments
Control Unit
More Rosemount Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL