Sign In
Upload
Manuals
Brands
Panametrics Manuals
Transmitter
DigitalFlow XGF868i
Panametrics DigitalFlow XGF868i Manuals
Manuals and User Guides for Panametrics DigitalFlow XGF868i. We have
2
Panametrics DigitalFlow XGF868i manuals available for free PDF download: Startup Manual, Service Manual
Panametrics DigitalFlow XGF868i Startup Manual (90 pages)
Flare Gas Mass Flow Ultrasonic Transmitter
Brand:
Panametrics
| Category:
Transmitter
| Size: 3 MB
Table of Contents
Table of Contents
9
Chapter 1. Installation
11
Introduction
11
Unpacking
11
Site Considerations
12
Electronics Enclosure Location
12
Flowcell Location
12
Transducer Location
12
Cable Lengths
13
Temperature and Pressure Transmitters
13
Transducer Cables
13
Installing a Flowcell
13
Installing Temperature and Pressure Transmitters
14
Mounting the Xgf868I Electronics Enclosure
15
Making the Electrical Connections
15
Wiring the Line Power
17
Wiring the Transducers and Preamplifiers
18
Wiring Std 0/4-20 Ma Analog Outputs
21
Wiring the Serial Port
22
Wiring the Option Cards
24
Chapter 2. Initial Setup
35
Introduction
35
Programming Methods
35
The Xgf868I Keypad
36
Entering Data in the GLOBL Menu
38
Entering Global System Data
38
Activating a Channel
41
Entering System Data for the Channel
42
Accessing the Channelx-System Submenu
42
Selecting Volumetric Units
42
Selecting Totalizer Units
42
Selecting Mass Flow Units
43
Entering Transducer and Pipe Parameters
43
Special Transducers
44
Pipe Data
44
Path and Axial Lengths
45
Chapter 4. Operation
49
Introduction
49
Powering up
50
The LCD Display
51
The Optional Panaview Display
52
Taking Measurements
53
Programming the LCD
53
Using the LCD Display
56
Panaview Display
57
Pausing Measurements
60
Chapter 5. Specifications
61
Operation and Performance
61
Fluid Types
61
Pipe Materials
61
Pipe Sizes
61
Flow Accuracy (Velocity)
61
Molecular Weight Accuracy
61
Mass Flow Accuracy
61
Repeatability
62
Rangeability (Overall)
62
Electronics
62
Flow Measurement
62
Enclosures
62
Dimensions (L X D)
62
Weight
62
Channels
63
Display
63
Keypad
63
Power Supplies
63
Power Consumption
63
5.2.10 Operating Temperature
63
Storage Temperature
63
5.2.12 Standard Inputs and Outputs
63
5.2.13 Optional Inputs and Outputs
63
5.2.14 Digital Interfaces
64
5.2.15 European Compliance
64
Wetted Ultrasonic Flow Transducers
64
Temperature Range
64
Pressure Range
64
Materials
64
Process Connections
64
Area Classifications
64
Insertion Mechanism
64
Standard Range
64
Gain
65
Temperature Range
65
Enclosure
65
Transducer Cables
66
Standard (Per Transducer Pair)
66
Optional
66
Options
66
Panaview™ PC-Resident Interface Software
66
Installation Flowcells
66
Pressure and Temperature Transducers
66
Appendix A. CE Mark Compliance
67
Introduction
67
Wiring
67
Appendix B. Data Records
69
Available Option Cards
69
Option Cards Installed
70
Setup Data
71
Appendix C. Measuring P and L Dimensions
75
Introduction
75
Measuring P and L
75
Advertisement
Panametrics DigitalFlow XGF868i Service Manual (72 pages)
Panametrics Flare Gas Flow Transmitter
Brand:
Panametrics
| Category:
Transmitter
| Size: 2 MB
Table of Contents
Table of Contents
7
Chapter 1. Calibration
9
Introduction
9
Accessing the Calibration Menu
9
Calibrating and Testing the Analog Outputs
10
Preparing for Calibration
10
Calibrating the Low End of the Output Range
11
Calibrating the High End of the Output Range
11
Testing Output Linearity
11
Calibrating the Analog Inputs
12
Preparing for Calibration
13
Accessing the Calibration/Test Menu
13
Calibrating the RTD Inputs
14
Preparing for Calibration
14
Accessing the Calibration/Test Menu
14
Entering the Set Point
14
Entering the Slope
14
Testing the Frequency Outputs
14
Preparing for Testing
14
Testing the Output
16
Chapter 2. Error Codes
19
Introduction
19
Chapter 3. Diagnostics
25
Introduction
25
Displaying Diagnostic Parameters
25
Flowcell Problems
27
Gas Problems
27
Pipe Problems
27
Transducer Problems
28
Chapter 4. Parts Replacement
29
Introduction
29
Removing the Circuit Board Assembly
30
Replacing the LCD Display/Interconnect Board Subassembly
31
Replacing the Fuse
32
Replacing the User Program
33
Installing an Option Card
34
Attaching an Optional Heat Sink to an I/O Option Card
34
Assembling/Installing the Circuit Board Assembly
34
Assembling the Circuit Board Assembly
34
Installing the Circuit Board Assembly
36
Appendix A. Service Record
41
Introduction
41
Data Entry
41
Diagnostic Parameters
43
Appendix B. Calibration and Testing with Panaview
45
Introduction
45
Accessing the Calibration/Test Menu
46
Calibrating Slot 0 Analog Outputs
47
Calibrating Slot 1 Option Cards
49
Analog Outputs
50
Analog Inputs
51
RTD Inputs
52
Entering the Set Point
52
Entering the Slope
52
Testing Frequency Outputs
53
Testing the Xgf868I Software and Hardware
53
Uploading the Signal Array Data
54
Uploading the Xgf868I Memory
55
Testing the Xgf868I Hardware
56
Appendix C. Factory Tests
65
Introduction
65
Resetting the Number of Channels
65
Resetting the Xgf868I to Factory Defaults
65
Advertisement
Related Products
Panametrics DigitalFlow XGM868i
Panametrics DigitalFlow XGS868i
Panametrics PanaFlow XMT1000
Panametrics DigitalFlow XMT868i
Panametrics XMO2
Panametrics XDP-H2
Panametrics DigitalFlow GM868
Panametrics DigitalFlow GS868
Panametrics DigitalFlow DF868
Panametrics DigitalFlow GC868
Panametrics Categories
Measuring Instruments
Transmitter
Transducer
Industrial Equipment
Analytical Instruments
More Panametrics Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL