Panametrics DigitalFlow XGS868i Manuals
Manuals and User Guides for Panametrics DigitalFlow XGS868i. We have
2
Panametrics DigitalFlow XGS868i manuals available for free PDF download: Startup Manual, Service Manual
Panametrics DigitalFlow XGS868i Startup Manual (86 pages)
Steam Ultrasonic Mass Flow Transmitter
Brand:
Panametrics
| Category:
Transmitter
| Size: 2 MB
Table of Contents
Table of Contents
7
Chapter 1. Installation
9
Introduction
9
Unpacking
9
Site Considerations
10
Electronics Enclosure Location
10
Flowcell Location
11
Transducer Location
11
Cable Lengths
11
Temperature and Pressure Transmitters
11
Transducer Cables
11
Installing a Flowcell
12
Installing Temperature and Pressure Transmitters
12
Mounting the Xgs868I Electronics Enclosure
13
Making the Electrical Connections
13
Wiring the Line Power
15
Wiring the Transducers
16
Wiring Std 0/4-20 Ma Analog Outputs
18
Wiring the Serial Port
18
Wiring the Option Cards
21
Chapter 2. Initial Setup
35
Introduction
35
Programming Methods
35
The Xgs868I Enclosure Keypad
36
Entering Data in the Global Menu
38
Entering Global System Data
38
Activating a Channel
41
Entering System Data for the Channel
42
Accessing the Channelx-System Submenu
42
Entering Transducer and Pipe Parameters
44
Special Transducers
44
Pipe Data
45
Chapter 3. Operation
49
Introduction
49
Powering up
50
The LCD Display
51
The Optional Panaview Display
52
Taking Measurements
53
Programming the LCD
53
Using the LCD Display
55
Panaview Display
56
Pausing Measurement
59
Chapter 4. Specifications
61
General Specifications
61
Hardware Configuration
61
Environmental
61
Velocity Accuracy
61
Velocity Range
61
Rangeability
61
Repeatability
61
Electrical Specifications
61
Power Supply
62
Power Consumption
62
Operating Mode
62
European Compliance
62
Input/Output Specifications
62
Preamplifier
63
Flow Transducer Specifications
63
Type
63
Temperature Range
63
Pressure Range
63
Materials
63
Physical
63
Flowcell Specifications
64
Spoolpiece
64
Cold Tap
64
Pipe Size & Materials
64
Appendix A. CE Mark Compliance
65
Introduction
65
Wiring
65
Appendix B. Data Records
67
Available Option Cards
67
Option Cards Installed
68
Setup Data
69
Appendix C. Measuring P and L Dimensions
73
Introduction
73
Measuring P and L
73
Advertisement
Panametrics DigitalFlow XGS868i Service Manual (74 pages)
Steam Ultrasonic Mass Flow Transmitter (1 & 2 Channel)
Brand:
Panametrics
| Category:
Transmitter
| Size: 3 MB
Table of Contents
Table of Contents
7
Chapter 1. Calibration
9
Introduction
9
Accessing the Calibration Menu
9
Calibrating and Testing Analog Outputs
10
Preparing for Calibration
10
Calibrating the Low End of the Output Range
11
Calibrating the High End of the Output Range
11
Testing Output Linearity
11
Calibrating Analog Inputs
12
Preparing for Calibration
13
Accessing the Calibration Menu
13
Calibrating RTD Inputs
14
Preparing for Calibration
14
Accessing the Calibration/Test Menu
14
Entering the Set Point
14
Entering the Slope
14
Testing Alarm Relays
15
Preparing for Testing
15
Testing the Relay
15
Testing Totalizer Outputs
16
Preparing for Testing
16
Testing the Output
17
Testing the Frequency Outputs
18
Preparing for Testing
18
Testing the Output
18
Chapter 2. Error Codes
21
Introduction
21
Chapter 3. Diagnostics
25
Introduction
25
Displaying Diagnostic Parameters
25
Flowcell Problems
28
Gas Problems
28
Pipe Problems
29
Transducer Problems
30
Chapter 4. Parts Replacement
31
Introduction
31
Removing the Circuit Board Assembly
32
Replacing the LCD Display/Interconnect Board Subassembly
33
Replacing the Fuse
34
Replacing the User Program
35
Installing an Option Card
36
Attaching an Optional Heat Sink to an I/O Option Card
36
Assembling/Installing the Circuit Board Assembly
37
Assembling the Circuit Board Assembly
37
Installing the Circuit Board Assembly
38
Appendix A. Service Record
43
Introduction
43
Data Entry
43
Diagnostic Parameters
45
Appendix B. Calibration and Testing with Panaview
47
Introduction
47
Accessing the Calibration/Test Menu
48
Calibrating Slot 0 Analog Outputs
49
Calibrating Slot 1 Option Cards
51
Analog Outputs
52
Analog Inputs
53
RTD Inputs
54
Entering the Set Point
54
Entering the Slope
54
Testing Alarm Relays
55
Testing Totalizer Outputs
56
Testing Frequency Outputs
56
Testing Xgs868I Software and Hardware
57
Uploading Signal Array Data
57
Uploading Xgs868I Memory
59
Testing Xgs868I Hardware
60
Appendix C. Factory Tests
67
Introduction
67
Resetting the Number of Channels
67
Resetting the Xgs868I to Factory Defaults
67
Advertisement
Related Products
Panametrics DigitalFlow XGF868i
Panametrics DigitalFlow XGM868i
Panametrics PanaFlow XMT1000
Panametrics DigitalFlow XMT868i
Panametrics XMO2
Panametrics XDP-H2
Panametrics DigitalFlow GM868
Panametrics DigitalFlow GS868
Panametrics DigitalFlow DF868
Panametrics DigitalFlow GC868
Panametrics Categories
Measuring Instruments
Transmitter
Transducer
Industrial Equipment
Monitor
More Panametrics Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL