Sign In
Upload
Manuals
Brands
Panametrics Manuals
Measuring Instruments
DigitalFlow GC868
Panametrics DigitalFlow GC868 Flowmeter Manuals
Manuals and User Guides for Panametrics DigitalFlow GC868 Flowmeter. We have
3
Panametrics DigitalFlow GC868 Flowmeter manuals available for free PDF download: Programming Manual, Startup Manual, Service Manual
Panametrics DigitalFlow GC868 Programming Manual (134 pages)
Panametrics Gas Clamp-On Ultrasonic Flowmeter
Brand:
Panametrics
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
7
Chapter 1. Programming Site Data
12
Introduction
12
Using the Keypad
12
Obtaining On-Line Help
16
Using the Console Control Keys
17
Audio Alarm Volume
17
Stopwatch Totalizer
17
Display Brightness
17
Display Contrast
17
Entering Programming Mode
18
Entering Channel Data
19
Activating a Channel
19
Procedure Options
20
Entering System Data for a Channel
20
Entering Pipe Data
21
Special Transducers
21
Wedge Temperature
22
Pipe Material
22
Pipe OD
22
Pipe Wall
22
Fluid Type
22
Reynolds Correction
22
Calibration Factor
22
Number of Traverses
23
Transducer Spacing
23
Procedure Options
23
Setting up Inputs/Outputs
23
Zero Cutoff
23
Temperature Input
23
Pressure Input
24
Procedure Options
24
Entering Setup Data
25
Setting Signal Limits
25
Setting Advanced Parameters
29
Procedure Options
32
Entering Global Data
32
Setting the Clock
33
Setting the Date
33
Setting the Time
33
Entering Global System Data
33
Mass Flow (Static)
34
Procedure Options
34
Setting up Global Inputs/Outputs
34
Selecting Error Handling
35
Setting up Option Cards
35
Procedure Options
38
Setting up Communications
38
MODBUS (RS485) Parameters
39
MODBUS/TCP Parameters
39
MODBUS Register Map
39
Activating Security
41
Procedure Options
42
Saving Site Files
43
Recalling Site Files
43
Chapter 2. Displaying Data
45
Introduction
46
The DUAL Submenu
47
The GRAPH Submenu
48
Setting up the GRAPH Format
48
Using the GRAPH Format
48
The LOG Submenu
50
Numeric Format
51
Graphical Format
51
Displaying the Transducer Signal
53
Setting the LCD Backlight
55
Activating Sleep Mode
56
Chapter 3. Logging Data
57
Introduction
58
Creating a Standard Log
59
Log Type
60
STARTTIME Prompt
60
START DATE Prompt
60
END TIME Prompt
60
END DATE Prompt
61
DURATION Prompt
61
LOG TIME Prompt
61
TIME INCREMENT Prompt
61
Procedure Options
61
Checking the Memory
62
Stopping a Log
62
Procedure Options
63
Creating an ERROR Log
63
Log Type
64
STARTTIME Prompt
64
START DATE Prompt
64
Procedure Options
64
Chapter 4. Printing Data
65
Introduction
66
Printing Live Data
66
Numeric Format
67
Graphical Format
68
Printing Logs
69
Numeric Format
70
Graphical Format
70
Printing a Site File
71
Stop Printing
71
Setting up a Printer
72
Printing Signal Array Data
73
Printing RTD Data
74
Chapter 5. Clearing Data
76
Introduction
76
Reset Totals
76
Procedure Options
76
Deleting Site Files
77
Procedure Options
77
Deleting Log Files
77
Chapter 6. Serial Communications
79
Introduction
80
Wiring the RS232 Interface
80
Checking the GC868 Baud Rate
80
Setting up the Terminal Software
81
Windows 9X/NT Systems
81
The Optional RS485 Serial Interface
82
Interface Converter Mounting
82
Point-To-Point Wiring
83
Multi-Point Wiring
84
Reconfiguring a Serial Interface Converter
84
Wiring the System
85
Setting up an Ethernet Connection
86
Setting up a MODBUS/TCP Connection
87
Appendix A. Menu Maps
89
Appendix B. Data Records
99
Option Cards Installed
100
Initial Setup Data
101
Appendix C. Programming with Panaview
103
Introduction
104
Wiring the RS232 Interface
104
Setting up the Communicatio-Ns Port
104
Setting up Ethernet Communicatio-Ns
106
Adding the GC868
107
Editing Meter Properties
108
Setting the Meter Clock
109
Reading Transducer Signals
109
Plotting Transducer Signals
109
Saving Transducer Signals
109
Clearing Totalizers
109
Handling Site Files
109
Saving an Existing Site to the Meter
113
Saving a New Site to the Meter
113
Saving a Site to the PC
113
Clearing a Site from the Meter
114
Saving a Site in Text Form
114
Changing Meter Settings
115
Appendix D. Foundation Fieldbus Communications
119
Optional Measurements
120
Configuration Utility Setup
121
Selecting the Desired Measurements
121
Selecting Units for AI Blocks
123
Resetting Instrument Totalizers
124
Function Block Application
125
Advertisement
Panametrics DigitalFlow GC868 Startup Manual (90 pages)
Gas Clamp-On Ultrasonic Flowmeter
Brand:
Panametrics
| Category:
Measuring Instruments
| Size: 4 MB
Table of Contents
Table of Contents
7
Chapter 1. Installation
12
Introduction
12
Unpacking
12
Site Considerations
12
Electronics Console Location
12
Installation Location
12
Transducer Location
13
Cable Lengths
13
Temperature and Pressure Transmitters
13
Transducer Cables
13
Installing Damping Material, Transducers and Fixtures
14
Application Requirements
14
Preparing the Pipe
18
Obtaining the Transducer Spacing
20
Installing the PI Fixture and Transducers
23
Installing Damping Material
28
Installing DMP-1 Damping Material with CFG-V Series Fixtures
28
Installing DMP-1 Damping Material with PI Fixture
30
Installing DMP-3 Compound with All Fixtures
31
Installing the PDJ Damping Jacket
32
Installing Temperature and Pressure Transmitters
33
Mounting the GC868 Electronic Console
34
Making Electrical Connections
34
Wiring the Line Power
35
Wiring the Transducers
36
Wiring the 0/4-20 Ma Analog Outputs
37
Wiring the Serial Port
37
Wiring an Alarms Option Card
40
Wiring a Totalizer/Frequency Outputs Option Card
42
Wiring an RTD Inputs Option Card
43
Wiring the MODBUS Option Card
43
Chapter 2. Initial Setup
49
Introduction
50
Navigating through the User Program
50
Accessing the User Program
51
Activating a Channel
52
1-Channel Meter
52
And 2-Channel Meters
52
Entering System Data for a Channel
52
A 1-Channel Meter
52
A 2-Channel Meter
53
1- and 2-Channel Meters
53
Mass Flow (Static)
54
Entering Pipe Data
55
Special Transducers
55
Wedge Temperature
55
Pipe Material
55
Pipe OD
56
Pipe Wall
56
Fluid Type
56
Reynolds Correction
56
Calibration Factor
56
Number of Traverses
56
Transducer Spacing
57
Procedure Options
57
Chapter 3. Operation
57
Introduction
62
Powering up
62
Using the Display
63
Taking Measurements
64
Foundation Fieldbus Communications
65
Chapter 4. Specifications
67
General
68
Hardware Configuration
68
Flow Accuracy
68
Environmental
68
Range
68
Rangeability (Overall)
68
Repeatability
68
Response Time
68
Electrical
68
Power Supply
68
Hazardous (Classified)Location Compliance
69
Input/Output Specifications
69
Operational
70
Flow Computer (Built-In)
70
Data Logging
70
Display Functions
70
Printer Signal Output
70
Transducer
70
Transducer Type
70
Temperature Range
70
Frequencies
70
Materials
70
Pipe Requirements
71
Pipe Size
71
Pressure Requirements
71
Pipe Wall Thickness
71
Fluid Composition
71
Appendix A. CE Mark Compliance
73
Introduction
74
Wiring
74
External Grounding
74
Appendix B. Data Records
75
Option Cards Installed
76
Initial Setup Data
77
Appendix C. Optional Enclosures
79
Introduction
80
Rack Mount Enclosure
80
Rack Mount Wiring
80
Rack Mount Front Panel
80
Panametrics DigitalFlow GC868 Service Manual (64 pages)
Panametrics Gas Clamp-On Ultrasonic Flowmeter
Brand:
Panametrics
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Table of Contents
7
Chapter 1. Calibration
10
Introduction
10
Menu Map
10
Calibrating the Analog Outputs
10
Accessing the Calibration Menu
12
Calibrating the Low End of the Output Range
12
Calibrating the High End of the Output Range
12
Testing the Analog Output Linearity
12
Procedure Options
12
Calibrating the Analog Inputs
13
Accessing the Calibration Menu
15
Alow Option = [F1]
15
Ahigh Option = [F2]
15
Ma Option = [F3]
15
Ma Option = [F4]
15
Procedure Options
15
Calibrating the RTD Inputs
15
Probe Option = [F1]
16
Set Point Temperature
16
Slope Point Temperature
16
Numer Option = [F2]
16
Set Number
16
Slope Number
16
Procedure Options
16
Testing the Alarm Relays
17
Accessing the Calibration Menu
17
Procedure Options
18
Testing the Totalizer/Frequency Outputs
18
Accessing the Calibration Menu
19
Entering Frequency
19
Entering Pulse Number
19
Procedure Options
19
Chapter 2. Error Codes and Screen Messages
23
Introduction
24
E0: no Error
25
E1: Low Signal
25
E2: Sound Speed Error
25
E3: Velocity Range
25
E4: Signal Quality
25
E5: Amplitude Error
25
E6: Cycle Skip, Accel
26
E7: Analog out Error
26
2.10 E8: Temp in
26
E9: Press in
26
E10: Special Input
26
2.13 E11: Not Used
26
2.14 E12: Not Used
26
2.15 E13: over Range
26
E14: Totals Overflow
26
E15: Equation Limit
27
2.18 E16: High Signal
27
Screen Messages
27
Chapter 3. Diagnostics
30
Introduction
30
Displaying Diagnostic Parameters
30
Diagnostic Record
33
Flowcell Problems
33
Gas Problems
33
Pipe Problems
34
Transducer Problems
34
Chapter 4. Parts Replacement
35
Introduction
36
Fuse Replacement
36
Removing the Printed Circuit Board
37
Replacing the EPROM
38
Installing an Option Card
39
Replacing the LCD Display
39
Installing the Printed Circuit Board
40
Spare Parts
42
Appendix A. Service Record
45
Introduction
46
Data Entry
46
Diagnostic Parameters
48
Appendix B. Optional Enclosures
49
Introduction
50
Rack Mount Enclosure
50
Rack Mount Fuse Replacement
50
Rack Mount Option Card Installation
51
Rack Mount EPROM Replacement
52
Rack Mount LCD Display Replacement
53
Rack Mount Printed Circuit Board Replacement
54
Circuit Board Removal
54
Circuit Board Installation
55
Advertisement
Advertisement
Related Products
Panametrics GF868
Panametrics DigitalFlow GM868
Panametrics DigitalFlow GS868
Panametrics DigitalFlow XMT868i
Panametrics DigitalFlow DF868
Panametrics DigitalFlow XGF868i
Panametrics DigitalFlow XGM868i
Panametrics DigitalFlow XGS868i
Panametrics 910-198E
Panametrics Aurora H2O
Panametrics Categories
Measuring Instruments
Transmitter
Transducer
Industrial Equipment
Monitor
More Panametrics Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk