Sign In
Upload
Manuals
Brands
Optopol Manuals
Medical Equipment
SOCT Copernicus REVO
Optopol SOCT Copernicus REVO Tomography Manuals
Manuals and User Guides for Optopol SOCT Copernicus REVO Tomography. We have
4
Optopol SOCT Copernicus REVO Tomography manuals available for free PDF download: User Manual, Service Manual, Installation And Upgrade Manual
Optopol SOCT Copernicus REVO User Manual (374 pages)
Brand:
Optopol
| Category:
Medical Equipment
| Size: 29.22 MB
Table of Contents
Table of Contents
3
Description of the Device
13
Intended Use
13
Intended User
14
The Minimum Knowledge
14
Education Needed for Operating the Tomograph
14
Operating Skills
14
Occupational Skills
15
Job Requirements for the User
15
Places of Use
15
Patient Population
15
Proper Instrument Use
15
Contraindication
16
Instruction Manual Availability
16
Instruction Manual Applicability
16
Disposal
17
Protective Measures for It Systems
17
Cybersecurity Functions
17
System Overview
17
Authentication of Users
18
Auto-Logoff
18
Ensure Trusted Content
18
Cybersecurity Event
18
Recover
18
Other Implemented Mechanisms
19
Technical Data
20
Technical Data Revo Nx 130 / Revo Nx
20
Soct Copernicus Revo/ Soct Copernicus / Revo 60/Revo 80
21
Technical Data Revo Fc
22
Device Classification
23
Minimum Computer System Requirements
23
Capture Station
23
Review Station
24
Safety
25
Safety Information
25
Product Label
26
Safety Standards
28
Warnings
30
Cautions
34
General Notes
36
Notes on Use
38
Before Use
38
After Use
38
Unpacking and Installation
39
Unpacking
39
Connecting Cables
40
Device Connection
42
Factory Default Calibration and Configuration
44
Soct Software
45
Running Soct Application
45
Soct Application Structure
45
Patient Window
46
Patient List View
46
Customization of the Patient List View
47
Registering New Patients
47
Editing Personal Data
49
Unregistering Patients
49
Examination List
49
Deleting Exam/S
50
Connecting Scans Connected to the Wrong Patient
51
Exporting Examinations
51
Export with Anonymization
51
Importing Examinations
51
Filter
52
Output
52
Work List
53
Examination Acqusition Tab
54
Selection of Scan Pattern Mode
59
Selection of Scanning Program
60
Oct Biometry Programs
61
Oct Topography Programs
61
Oct Angiography Programs
61
Fundus Camera Programs
62
Oct + Fundus Photography
62
Selection of Protocol
63
Device Head Movement Controls
64
Eye Preview
65
Fundus Preview
66
Pslo Live Fundus Preview
66
Ir Preview
66
Operation on the Fundus Preview
68
Oving the Canning Rea
68
Rotation of the Scanning Angle
68
Moving the Internal Fixation Target
68
Changing the Scan Width
68
Changing the Scans Distance
69
Fixation Target Change
69
Customizing Scan Parameters
69
Live Oct Preview
72
Itracking
73
Acceptance Window for a 3D Scan
73
Conducting Examination
76
Preparation for Examination
76
Acquisition Modes Description
77
Full Auto Mode
77
Semi Auto Mode
77
Manual Mode
79
Scanning Programs Description
80
Retina Examination
80
Central Examination
80
Disc Area Examination
81
Oct Angiography Examination
82
Oct Angiography Mosaic Mode
83
Anterior Measurement
85
Wide Anterior Programs
86
Biometry Program
89
Topography Program
89
Fundus Image Revo Fc
89
Full Range Examination Mode
94
Anterior Full Range Examination Mode
94
Central Full Range Examination Mode
95
External Fixation
96
Chorioretinal/Vitreoretinal Mode
96
Examination Tips
97
Tips for Automatic Eye Alignment
97
Tips for Manual Eye Alignment
97
Auto C-Gate Issues
98
Tips to Successfully Scan Difficult Patients
101
Critera for Exam Acceptance
103
Evaluation of Oct Fundus Reconstruction for Posterior 3D Exams
103
Evaluation of Oct Tomograms for Posterior and Anterior Scans
107
Oct Images
109
Fundus Photography
110
3D Examination Acceptance Criteria
110
Saccades
110
Banding
110
Weak Local Signal
111
Blinks
111
Floaters
111
Cropped Image
111
Oct Angiography Acceptance Criteria
111
Segmentation Errors
111
Image Quality
112
Result Review
114
Type of View Mode
114
[Single] Tab Screen
114
[Both Eyes] Tab Screen
114
[Comparison] Tab Screen
114
[Progression] Tab Screen
114
Lock Function
114
Types of Analysis
115
Single Retina Analysis
115
AI Denoise
115
3D Tab
116
10 Posterior Analysis
117
Retina Thickness Analysis
117
Single Tab
117
Both Eyes Tab
121
Comparison
125
Progression
126
Optic Nerve Head Analysis
129
Advanced View - Retina and Optic Nerve Head Analysis
138
Strucutre & Function - Combined Oct and Vf Report
139
Relationships between Vf and Rnfl/Ganglion Maps
142
Requirements that Must be Met for Loading Perimeter Tests in the Soct Application
142
Structure & Function - Vf Results Layer in Combined View
143
Structure & Function - Vf Locations Layer
145
Central Examination
148
Central 3D Examination
148
2D Scan Programs Results Review
149
Single B-Scan Examination Review
150
Raster Examination Results Review
151
Radial Examination Results Review
153
Cross Examination Results Review
154
3D Visualization
155
Manipulation of the 3D Cube
155
Selection of Displayed Layers
155
Operation Panel [Solid ]
156
[Solid] View
158
[Volume View]
159
11 Anterior Segment Analysis
160
Anterior Radial
163
[Single] Tab Screen
163
[Both Eyes] Tab Screen
165
[Comparison] Tab Screen
165
[Progression] Tab Screen
166
Edit Anterior Surface
168
Aod Measurement
169
Angle Measurement Tool
170
Caliper Tool
171
Tomogram Review Analysis
171
12 Full Screen Window
172
Fundus Reconstruction, Eye Preview or Pslo
172
Imaging Tools
173
Measurement Tools and Annotations
173
Brightness and Contrast Adjustment
174
Full Screen Mode Exit
175
Tomogram Window Manipulation
175
Edition of Recognized Layers
176
Manual Disc Contour Edition
177
Redraw the Disc Contour
178
13 Print
180
Posterior Segment Examination Reports Outputs Retina 3D
180
Disc 3D
183
Optic Nerve Head Analysis Reports
185
Topography Examination Reports
191
Fundus Examination Reports
195
Angiography Examination Reports
197
Disc Oct-Aexamination Reports
201
Biometry Examination Reports
205
Multi B-Scan Report
206
Manually Select Tomograms
207
Multi B-Scan Report for both and Comparison View
207
Single Tomogram Report
208
Select Desired Printer
208
14 Output
209
15 Selecting Fundus Photo
210
Adding Fundus Photo to the Examination
210
Fundus Image Registration Correction
212
Linking a Fundus Photo to an Examination
212
16 Examinations Correlation
214
Oct-Oct Registration
214
Automatic Correlation
214
Manual Registration
215
Fundus Correletion
215
Automatic Correlation
215
Manual Correlation
217
Moving the Overlaid Oct Image
218
Closing Fundus and Oct Correlation Window
219
Extracting Tomograms from a 3D Exam
219
Fundus Camera - Result Review
220
Color Fundus Photo
220
Color Fundus Photo
221
Color Fundus Photo Full Screen View
221
Color Fundus Photo [Both] View
222
Color Fundus Photo [Comparison] View
222
17 Angiography Oct
223
Retina Oct-A
223
[Single] View - Standard
223
[Single] View - Detailed
224
Angio Oct Analysis
226
Quantification Tools: FAZ, VFA, NFA
234
Faz Tool
234
Vfa Tool
237
Nfa Tool
238
Quantification Maps
240
Angio Oct Analysis Table
244
[Both] View
244
[Comparison] View
246
[Progression] View
247
Motion Correction
248
Motion Correction in 3D Examinations
249
Disc Oct-A
250
[Single] View
250
[Both] View
251
Angio Disc Comparison View
253
[Progression] View
253
Mosaic
254
Correlation Status
256
Select Screen
256
Operation on the Mosaic
256
18 Biometry Oct
259
Biometry Acquisition Mode
261
Full Auto Mode
263
Semi Auto Mode
264
Acceptance Screen
266
White to White
267
Result Review
268
Single View
269
Both View
271
Full Screen
271
19 Iol Calculation Tab
274
Performing Iol Calculation
275
Marking Implemented Lenses
277
Iol Editor
277
Importing Iol Data
278
Exporting Iol Data
279
Adding Lenses Manually
279
Deleting Lenses Manually
279
Viewing the List of Lenses
279
Editing Iol Data
280
Adding Additional Power Ranges and Increments
281
20 Topography Oct
282
Topography - Safety Notes
282
Topography Acquisition Mode
284
Full Auto Mode
285
Semi Auto Mode
286
Acceptance Screen
287
Total Quality Factor
288
Result Review
288
[Single] View
288
[Both] View
290
[Comparison] View
291
[Progression] View
291
Analysis
292
Central Keratometry - Simk
292
Keratometry (Meridian)
292
Keratometry (Semimeridian)
293
Keratoconus Screening
293
Pachymetry
297
Map Types
297
Color Scale - Standards
300
21 Calibration
304
Calibration Procedure Preparation
304
Topography Calibration
305
Intitial Topography Calibration Procedure
305
Standard Calibration
306
Calibration Process
306
Axial Length (Biometry) Calibration
308
Biometry Calibration with the Iol Calculation Tab Unactivated
308
Biometry Calibration with the Iol Calculation Tab Activated
309
Calibration Process
310
Entering Biometry Calibration Parameters
311
Common Calibration
311
22 Setup Window
315
General
315
Database
316
Storage
318
Users Accounts
319
Creating User Accounts
320
Ldap Settings
321
Preferences
322
Cmdl Interface
322
Devices Setup
323
Parameters Tab
325
Voice Messages
326
Results Settings
327
Anonymization
328
Visual Field
331
Input Settings Window
332
Edit Disease List Window
333
Output Settings
333
Output Set Window
333
I. Exporting Tomograms with or Without AI Denoise
334
Creating an Output Set
334
Graphic File Standard
334
DICOM C-Storage Output Set
336
Backup
337
Recovery
338
Dicom
338
System Settings
339
Mwl Settings
340
C-Storage
341
Info Tab
341
Patient Record Change Traceability and Logreader Software
341
23 Maintenance and Cleaning Procedure
343
Routine Cleaning
343
Software Maintenance Activities
344
Hard Disk Defragmentation
344
Ordering Consumables
345
Fuse
346
Blown Fuses Exchange
346
24 Network Configuration
347
Network Connection Configuration
347
Soct Network
347
Soct Software - Viewing Station Configuration
348
25 Remote Connection
350
Pts Application for Structure & Function Report
350
26 Environmental Conditions
354
27 Warranty and Service
355
28 Utilization
355
Advertisement
Optopol SOCT Copernicus REVO User Manual (132 pages)
Brand:
Optopol
| Category:
Medical Equipment
| Size: 7.49 MB
Table of Contents
Section 1
3
Table of Contents
3
Description of the Device
8
Intend of Use
8
Intended User
8
The Minimum Knowledge
8
Education Needed for Operating the Tomographer
8
Operating Skills
9
Occupational Skills
9
Job Requirements for the User
9
Contraindication
9
Instruction Manual Availability
10
Instruction Manual Applicability
10
Disposal
10
Device Classification
11
Technical Data
11
Minimum Computer System Requirements
12
Capture Station
12
Review Station
12
Safety
13
Safety Information
13
Product Label
14
Safety Standards
15
Notes on Use
17
Before Use
17
After Use
17
Unpacking and Installation
18
Unpacking
18
Connecting Cables
19
Device Connection
20
Factory Default Calibration and Configuration
21
Soct Copernicus Revo Software
22
Running Soct Copernicus Revo Application
22
Soct Copernicus Revo Application Structure
22
Figure 1 Login Screen
22
Patient Window
23
Figure 2 Patient Tab
23
Patient List View
24
Registering New Patients
24
Figure 3 Patient List
24
Figure 4 Patient Edit Screen
24
Editing Personal Data
25
Figure 5 Examination List
26
Examination List
26
Unregistering Patients
26
Delete Exam/S
27
Export Examination
27
Import Examination
27
Filter
28
Figure 6 Filter Panel
28
Examination Window
29
Figure 7.Examination Window View
29
Selection of Scan Pattern Mode
32
Selection of Scanning Program
33
Selection of Protocol
34
Figure 8. Protocol Selection Tab
34
Figure 10. Device Movement Controls
35
Figure 9. Follow up Window Allows to Select Previous Examinations Parameters
35
Device Head Movement Controls
35
Follow up
35
Eye Preview
37
Figure 11. Movement Control Buttons
37
Figure 12.Device Aligns to the Place of Clicking on the Preview
37
Figure 13. Properly Aligned Measurement Head Position
37
Pslo Live Fundus Preview
38
Oving the Canning Rea
38
Rotation of the Scanning Angle
38
Moving the Internal Eye Fixation Target
38
Fixation Target Change
39
Customizing Scan Parameters
39
Figure 14. Fixation Target Selection
39
Figure 15. Examination Settings Panel
39
Figure 16. Tomogram Preview Images, Manual Position Adjustment
41
Live Oct Preview
41
Preparing for Examination
42
Conducting Examination
42
Acquisition Modes Description
43
Full Auto Mode
43
Semi Auto Mode
43
Figure 17. Full Auto Examination
43
Figure 18. Semi Auto Examination
43
Figure 19. Semi Automatic Examination Mode
43
Figure 20. Proper Quality and Position of the Tomogram
44
Manual Mode
45
Figure 21. Manual Examination Mode
45
Figure 22. Manual Examination Process. Scan Optimization and Tomogram Position Alignment
45
Figure 23. Proper Position and Quality the Tomogram
45
Figure 24. Proper Alignment of Retina Tomogram
46
Scanning Programs Description
46
Retina Examination
46
Central Examination
47
Disc Area Examination
47
Figure 25. Central Examination Proper Scan Alignment
47
Figure 26. Proper Disk Examination Alighnment
47
Anterior Measurement
48
Figure 27. Proper Anterior Measurement Alignment
48
Figure 28. Single Angle Measurement Proper Alignment
49
Figure 29.Single Angle Measurement Proper Alignment
49
Wide Anterior Programs
50
Figure 30.Side Views of Anterior Adapter
50
Figure 31. Anterior Adapter Mounting
50
Figure 33. Wide Cornea Scan Proper Alignment
51
Figure 32. Anterior Adapter Mounting. Rotate to Lock
51
External Fixation
52
Chorioretinal/Vitreoretinal Mode
52
Figure 34. Angle to Angle Scan Proper Alignment
52
Figure 35. Difference in Chorioretinal and Vitreoretinal Scanning Mode
52
Examination Tips
53
Figure 36. Figure 30. Properly Aligned Retina between Dashed Lines
53
Figure 37. Improper-Flipped Tomogram Preview
53
Figure 38. Shadow on Tomogram, Grab and Drag Towards Left Side
53
Figure 39. Shadow on Tomogram, Grab and Drag Towards Right Side
54
Figure 40. Proper Live Eye Preview While Manual Acquire Mode
54
Single Retina Analysis
55
Types of Analysis
55
Progression] Tab Screen
55
Both Eyes] Tab Screen
55
Comparison] Tab Screen
55
Single] Tab Screen
55
Type of View Mode
55
Result Review
55
Posterior Analysis
56
Retina Thickness Analysis
56
Single Tab
56
Both Eyes Tab
59
Comparison
63
Progression
64
Optic Nerve Head Analysis
67
Figure 41 Disc 3D [Single] Tab
67
Figure 42 Disc [Both] Tab
70
Figure 43 Progression 3D Disc
72
Figure 44. Central Examination Single Scan Review Window
74
Central Examination Analysis
74
Scan Programs Results Review
75
Single B-Scan Examination Review
76
Figure 45. Single Scan View
76
Figure 46. Single B-Scan both Eyes Review
76
Figure 47. Single B-Scan Comparison Window
76
Raster Examination Results Review
77
Figure 48. Single B Scan Progression Window
77
Figure 49. Retina Raster, Single Scan View
77
Figure 50. Central Raster Single Scan View
77
Figure 51. Raster both Eyes View
78
Figure 52. Raster Scan Comparison
78
Figure 53. Raster Progression View
78
Figure 55. Cross Scan Horizontal B-Scan View
79
Figure 56. Cross Scan Vertical B-Scan View
79
Radial Examination Results Review
79
Figure 54. Radial Examination Single View
79
Cross Examination Results Review
79
Visualization
80
Anipulation of the 3D Cube
80
Selection of Displayed Layers
80
Operation Panel
81
Solid] View
83
Figure 57 3D Solid View
83
Volume View]
84
Figure 58 Volume View
84
Anterior Segment Analysis
85
Figure 59 Short Cornea Scan
85
Figure 60 Short Anterior Angle Scan
85
Figure 61 Sclera and Cornea Wide Anterior 11 MM Scan
86
Figure 62 Angle to Angle View. Sample of Wide Anterior B-Scan
86
Anterior Radial
87
Single] Tab Screen
87
Figure 63 Single Anterior Radial
87
Both Eyes] Tab Screen
90
Comparison] Tab Screen
90
Progression] Tab Screen
91
Figure 64 Progression Anterior Radial Maps View
91
Figure 65 Anterior Progression Tomogram View
92
Edit Anterior Surface
93
Figure 66 Edit Anterior Layer
93
Aod Measurement
94
Angle Measurement Tool
95
Tomogram Review Analysis
95
Fundus Reconstruction, Eye Preview or Pslo
96
Figure 1 Full Screen Tomogram
96
Figure 2 the Choice of Eye Preview
96
Fullscreen Window
96
Imaging Tools
97
Selection and Layers Edition
97
Measurement Tools and Annotations
97
Figure 3 Imaging Tools
97
Figure 4 Selection and Layers Edition
97
Figure 5 Measurement Tools
97
Figure 6 Tab of Tomogram Annotations
98
Figure 7 Regulacja JasnośCI I Kontrastu
98
Full Screen Mode Exit
98
Brightness and Contrast Adjustment
98
Import Fundus Images
99
Adding Fundus Photo to the Examination
99
Figure 67 Fundus Registration Screen
99
Examinations Correlation
100
Manual Registration
100
Figure 68 Exam Registration Screen
100
Tomogram Window Manipulation
101
Figure 69. Tomogram Display Options Window
101
Edition of Recognized Layers
102
Angio Retina
103
Single] View
103
Figure 70 Single Angiography View
103
Angiogram Object
104
Enface Window
105
Tomogram Window
105
Setup Window
106
General
106
Database
107
Storage
108
Users Accounts
110
Preferences
111
Protocols Tab
111
Parameters Tab
113
Voice Messages
113
Results Settings
115
Backup
116
Maintenance and Cleaning Procedure
117
Routine Cleaning
117
Software Maintenance Activities
118
Hard Disk Defragmentation
118
Ordering Consumables
119
Fuse
119
Blown Fuses Exchange
119
Network Connection Configuration
120
Soct Network
120
Sharing SOCT Examination Database Folder(S) on Windows 7(Storage Locations)
121
SOCT Viewing Station Configuration/ SOCT PC
123
Faq
124
Environmental Conditions
125
Warranty and Service
126
Utilization
126
Troubleshooting
127
Section 2
130
Optopol SOCT Copernicus REVO Service Manual (194 pages)
Brand:
Optopol
| Category:
Medical Equipment
| Size: 20.54 MB
Table of Contents
Table of Contents
2
Introduction
5
Contact Details
5
Device Description
5
Disposal
5
Technical Data
6
Device Classification
6
Minimum System Requirements
6
Safety Instructions
8
Unpacking and Installation
9
Cables Connection
10
Proper Device Connection
12
Factory Default Calibration and Configuration
12
Safety Standards
13
Notes on Use
15
Before Use
15
After Use
15
SOCT Copernicus REVO SOFTWARE
15
E2V Camera
34
Troubleshooting
71
Installation Troubleshooting
71
Electronic Troubleshooting
73
Optical Troubleshooting
74
Maintenance Check Procedure
77
General Condition Check
77
Scantest Tool-Diagnostic Software Description
77
Opening and Closing the Device
81
Head Cover Opening
82
Neck Cover Removal
87
Bottom Cover Opening
89
Headrest Replacement/Removal
93
Removing the Device from Base Cover
95
Base Plate Assembly
99
Headrest Module Assembly
99
Bottom Cover Assembly
100
Neck Cover Assembly
100
Head Cover Assembly
102
Mechanics
105
Chinrest Module Repair
106
Right Left Movement Repair(Stepper Motor, Clutch, Thread Exchange,)
110
Back-Forward Movement Repair(Stepper Motor, Clutch, Thread Exchange)
113
Up-Down Movement Repair(Spring Exchange)
116
Spectrometer Regulation Module Replacement(Motor Replacement)
118
C-Gate Stepper Motor Replacement
119
Internal Fixation Focus Stepper Motor Replacement
121
OCT Focus Stepper Motor Replacement
126
Fan Replacement
129
Electronics
130
Device Block Scheme
130
Tools Needed to Replace Electronic Components
133
Fuse Exchange
133
Schurter Filter Replacement
134
Power Supply Module Replacement
135
CPU Replacement
137
Scanner Control Boards Replacement(X,Y Scanner Set)
140
Spectrometer Alignment Control Module Replacement
143
Internal Fixation Module Replacement
143
Position Sensors Replacement
144
Right-Left/ Back-Forward Movement Position Sensors Replacement
144
Up-Down Movement Position Sensors Replacement
145
Chinrest Module Extreme Position Sensors
146
C-Gate Base Position Sensor
147
Fixation Focus Base Position
148
OCT Focus Base Position Sensor
149
Preview Camera Replacement
150
USB Hub Replacement
152
SLED Diode Replacement
153
CPU Programming
157
Optics
158
Optical Scheme
158
Power Measurement/ Adjustment
159
Spectrum Height Check and Adjustment
162
Polarization Adjustment
164
Scanners Replacement /Alignment
169
Correcting Internal Fixation Position
177
Preview Camera Calibration(Left or Right)
178
Optics Cleaning
184
F a Q
186
Spare Parts List
187
Service Tools
194
Advertisement
Optopol SOCT Copernicus REVO Installation And Upgrade Manual (69 pages)
Brand:
Optopol
| Category:
Medical Equipment
| Size: 7.99 MB
Table of Contents
Table of Contents
3
Introduction
4
Proper Steps Selection! Must Read
4
Minimum Computer System Requirements
5
Capture Station
5
Review Station
5
Computer Preparation
6
Connecting USB 3.0 Communication Cable
6
Motherboard Drivers Installation
7
Partition Preparation
7
OS Windows 7 Configuration
8
Screen Resolution
8
Configure Power Balance Plan and Screen Saver
9
Windows Update
13
Install Windows Updates
13
Disable Automatic Windows Updates
16
Switch off Action Center Settings
16
Uninstall Windows 10 Update Reminder Number KB3035583
17
Antivirus Protection
18
Configure Date Format
21
SOCT Drivers Installation
23
Live Preview Camera Driver
23
E2V Camera
25
Software Installation on Windows 7, 10
28
SOCT Copernicus Software Configuration
33
Networking
38
Firebird Engine Installation
39
Mysql Database Engine Installation
50
SOCT Application Settings for Networking
59
Setting on the Viewing Station
63
Troubleshooting
65
Advertisement
Related Products
Optopol SOCT Copernicus REVO NX
Optopol SOCT Copernicus
Optopol SOCT Copernicus HR
Optopol SOCT Copernicus +
Optopol NX
Optopol REVO 60
Optopol REVO 80
Optopol REVO FC
Optopol REVO nx
Optopol REVO nx 130
Optopol Categories
Medical Equipment
More Optopol Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL